20
R
Re
eff
D
Diis
sp
plla
ayy
D
De
es
sc
crriip
pttiio
on
n &
& S
Se
ettttiin
ng
gs
s
D
D2
2 S
Syys
stte
em
m c
cttd
d......
D2.2.4
Identification No
Sets a different device modus for the cyclic communication of the
PROFIBUS interface
MFC300
complete functionality concerning the cyclic data
exchange of the coriolis mass flow meter MFC300
is supported (including manufacturer specific
extensions)
Profile
only the profile defined functions concerning the
cyclic data exchange are supported - no extras
D2.2.5
PB Cold Start
Reset?
N
No
o
terminates the function
Y
Ye
es
s
PROFIBUS cold start will be carried out at
once. The programming mode is terminat-
ed
N
No
otte
e::
During a PROFIBUS cold start nearly all parameter values of the
whole device will be set to their default values (e.g. the PROFIBUS
address will not be changed) without disconnecting an already
established connection to a PROFIBUS Master system
Current Device Revision
Use the display of the “MFC300 with PROFIBUS RS-485 Interface” to open the path:
“test\information\Profibus” ( == menu B3.5)
This menu will provide the following information:
KROHNE Ident No.
Software Revision of the PROFIBUS software
Date of Production