97
Part D
Technical Data and Dimensions
11.
Technical Data
11.1
Primary Head
CORIMASS MFS 3000 - ...
1.5
10
30
Measuring ranges (for water at
20
°
C
or 68
°
F)
Nominal value
1.5 kg/min or
3.3 lb/min
10 kg/min or
22 lb/min
30 kg/min or
66 lb/min
Flowrates:
min
0.035 kg/min or
0.007 lb/min
0.25 kg/min or
0.55 lb/min
0.75 kg/min or
1.65 lb/min
max
2.5 kg/min or
5.5 lb/min
13 kg/min or
29 lb/min
33.3 kg/min or
73.16 lb/min
Connections
Screw fittings
Standard
NPT (female)
Swagelock
Gyrolock
Ermeto 6
¼” F and M
6 mm (0.24”)
6 mm (0.24”)
Ermeto 8
¼” F and M
8 mm (0.31”)
8 mm (0.31”)
Ermeto 12
½” F and M
12 mm (0.47”)
12 mm (0.47”)
Flanges DIN 2635 / PN 40
ANSI 150 & 300RF
-
-
DN 15
½”
DN 15/25
½” / ¾”
Sanitary connections
on request
on request
on request
Pressure loss (for water at
nominal flowrate, 20
°
C or 68
°
F)
0.6 bar or 8.7 psig
1.6 bar or 23 psig
1.8 bar or 25.8 psig
Product parameters
Temperature
Standard
-50 to +80
°
C or
-58 - +176
°
F
-50 to +80
°
C or
-58 - +176
°
F
-50 to +80
°
C or
-58 - +176
°
F
Special vers.
-50 to +150
°
C or
-58 to +392
°
F
-50 to +200
°
C or
-58 to +392
°
F
-50 to +200
°
C or
-58 to +392
°
F
Density
10 - 2000 kg/m
3
or
0.6 - 125 lb/ft
3
10 - 2000 kg/m
3
or
0.6 - 125 lb/ft
3
10 - 2000 kg/m
3
or
0.6 - 125 lb/ft
3
Nominal Pressure
160 bar or 2300 psig
250 bar or 3600 psig
300 bar or 4320 psig
Density error limits
(0.5 - 2.0 g/cm
3
or 30 - 125 lb/ft
3
measuring range, field calib.)
±
0.007 g/cm
3
or
±
0.34 lb/ft
3
±
0.004 g/cm
3
or
±
0.15 lb/ft
3
±
0.002 g/cm
3
or
±
0.075 lb/ft
3
Thermal shock resistance
∆
T
≤
10 K or
≤
18
°
F per second
Ambient temperature
In operation
In storage
-30 to +60
°
C or -22 to +140
°
F
-50 to +85
°
C or -58 to +185
°
F
Materials
Measuring tube
CrNi steel 1.4435, 1.4571 or SS 316 L, 316 Ti - AISI, Hastelloy C
Housing
CrNi steel 1.4301 or SS 304 - AISI
Terminal box
die-cast aluminium with epoxy finish
Housing pressure resistance
information supplied on request
Protection category
(IEC 529 / EN 60529)
IP 67, equivalent to NEMA 6
Hazardous-duty versions
pending
Custody transfer
PTB certification
Special versions
Insulated measuring tube
on request
Flameproof enclosure
25 bar or 360 psig
5.411
94.08