Kramer Electronics Ltd.
VS-62H
– Protocol 3000
44
Function
Description
Syntax
Parameters/Attributes
Example
ROUTE?
Get layer routing.
This command
replaces all other routing
commands.
COMMAND
#ROUTE?
layer
,
dest
<CR>
FEEDBACK
~nn@ROUTE
layer
,
dest
,
src
<CR><LF>
layer
Layer Enumeration
1
– Video
2
– Audio
3
– Data
4
– IR
5
– USB
dest
*
– ALL
x
– disconnect, otherwise
destination id
src
– Source id
Get layer routing:
#ROUTE?
1,4
<CR>
SECUR
Start/stop security.
The permission
system works only if
security is enabled with
the “SECUR” command.
COMMAND
#SECUR
security_mode
<CR>
FEEDBACK
~nn@SECUR
security_mode
<CR><LF>
security_mode
–
0
– OFF (disables security)
1
– ON (enables security)
Enable the permission system:
#SECUR
0
<CR>
SECUR?
Get current security state.
The permission
system works only if
security is enabled with
the “SECUR” command.
COMMAND
#SECUR?
<CR>
FEEDBACK
~nn@SECUR
security_mode
<CR><LF>
security_mode
–
0
– OFF (disables security)
1
– ON (enables security)
#SECUR?
<CR>
SIGNAL?
Get input signal status.
COMMAND
#SIGNAL?
inp_id
<CR>
FEEDBACK
~nn@SIGNAL
inp_id
,
status
<CR><LF>
inp_id
– Input number
1
– Input 1
n
– Input n
status
– Signal status according to
signal validation:
0
– Off
1
– On
Get the input signal lock status
of IN 1:
#SIGNAL?
1
<CR>
SN?
Get device serial
number.
COMMAND
#SN?
<CR>
FEEDBACK
~nn@SN
serial_number
<CR><LF>
serial_number
– 14 decimal
digits, factory assigned
Get the device serial number:
#SN?
<CR>
TUNNEL-CTRL
LEGACY COMMAND.
Send an asynchronous
command to a remote
Step-in equipment.
COMMAND
#TUNNEL-CTRL
stage
,
stage_id
,
”command”
<CR>
FEEDBACK
None
stage
– Input/Output
0
– Input
1
– Output
stage_id
– Number of chosen stage
(1 to max number of inputs/outputs)
command
– Command to send to the
Step-in client
UPGRADE
Perform firmware
upgrade.
Not necessary for
some devices.
Firmware usually uploads
to a device via a
command like LDFW.
Reset the device to
complete the process.
COMMAND
#UPGRADE
<CR>
FEEDBACK
~nn@UPGRADE
OK
<CR><LF>
Perform firmware upgrade:
#UPGRADE
<CR>
VERSION?
Get firmware version
number.
COMMAND
#VERSION?
<CR>
FEEDBACK
~nn@VERSION
firmware_version
<CR><LF>
firmware_version
– XX.XX.XXXX
where the digit groups are:
major.minor.build version
Get the device firmware
version number:
#VERSION?
<CR>
VID
LEGACY COMMAND.
Set video switch state.
The GET command
identifies input switching
on Step-in clients.
The SET command is for
remote input switching on
Step-in clients
(essentially via by the
Web).
This is a legacy
command. New Step-in
modules support the
ROUTE command.
COMMAND
#VID
in>out
<CR>
FEEDBACK
~nn@VID
in>out
<CR><LF>
in
– Input number or '0' to disconnect
output
>
– Connection character between in
and out parameters
out
– Output number or '*' for all
outputs
Switch IN 1 to OUT 3:
#VID
1>3
<CR>
VID?
LEGACY COMMAND.
Get video switch state.
The GET command
identifies input switching
on Step-in clients.
The SET command is for
remote input switching on
Step-in clients
(essentially via by the
Web).
This is a legacy
command. New Step-in
modules support the
ROUTE command.
COMMAND
#VID?
out
<CR>
FEEDBACK
~nn@VID
in>out
<CR><LF>
in
– Input number or '0' to disconnect
output
>
– Connection character between in
and out parameters
out
– Output number or '*' for all
outputs
Switch IN 1 to OUT 3:
#VID
1>3
<CR>
VID-PATTERN
Set test pattern on output.
COMMAND
#VID-PATTERN
output_id
,
pattern_id
<CR>
FEEDBACK
~nn@VID-PATTERN
output_id
,
pattern_id
<CR><LF>
output_id
– 1 to number of system
outputs
pattern_id
– 1 to number of
system patterns
Switch PATTERN 1 to OUT 3:
#VID-PATTERN
3
,
1
<CR>