Kramer Electronics Ltd.
VS-62H
– Principles of Operation
13
Principles of Operation
This section describes the operating theory of the
VS-62H
and includes:
•
Automatic signal detection (see
).
•
).
•
).
Automatic Signal Detection
The
VS-62H
can automatically detect the presence of a video signal on an input based on the
presence of a video sync or clock signal.
Input Switching Modes
Manual Mode
In Manual switching mode, routing is performed according to the front panel button selection
or according to the remote command selection.
Automatic Mode
Automatic switching can be performed in either of the following ways:
•
Input priority
. Upon detection of an active input, the input with the highest priority is
automatically selected. Input priority is from the lowest input number (1) to the highest
(6).
•
Last Connected
. The device automatically selects the most recently connected input.
Should this source become inactive, the device automatically switches to the last
connected input that was active. When turning the device on and more than one input is
active, the input with the highest priority is selected.
If a manual selection is made when the device is in Automatic mode, the device enters
Manual Override mode. The manually selected input remains selected as long as it is active.
When a manually selected input becomes inactive, the device returns to Automatic mode.