6.4
Connecting a PC or Controller to the RS 485 Port
You can operate the
VP-4x8AK
via the RS-485 port from a distance of up to
1200m (3900ft) using any device equipped with an RS-485 port (for example,
a PC). For successful communication, you must set the RS-485 machine
number and bus termination.
To connect a device with a RS-485 port to the
VP-4x8AK
:
•
Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on
the RS-485 port on the rear panel of the
VP-4x8AK
•
Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on the
RS-485 port on the rear panel of the
VP-4x8AK
•
Connect the G pin on the RS-485 port of the PC to the G pin on the
RS-485 port on the rear panel of the
VP-4x8AK
6.5
Configuring the Ethernet Port
To configure the Ethernet port, you have to connect your PC to the
VP-4x8AK
either via the Ethernet (see
Section 6.5.1
) or via a serial port.
Once the machine is connected, you can configure the Ethernet port.
6.5.1
Connecting via the Ethernet
You can connect the
VP-4x8AK
via the ETHERNET in the following ways:
•
For direct connection to the PC, use a crossover cable (see
Section 6.5.1.1
)
•
For connection via a network hub or network router, use a
straight-through cable (see
Section 6.5.1.2
)
6.5.1.1 Connecting the ETHERNET Port Directly to a PC (Crossover Cable)
You can connect the Ethernet port of the machine to the Ethernet port on your
PC, via a crossover cable with RJ-45 connectors.
This type of connection is recommended for identification of the factory default
IP Address
1
After connecting the Ethernet port, configure your PC as follows:
of the
VP-4x8AK
during the initial configuration
1. Right-click the My Network Places icon on your desktop.
2. Select
Properties
.
3. Right-click Local Area Connection Properties.
1 The default IP address is 192.168.1.39