Communication Parameters
36
11 Communication Parameters
Table 5
lists the communication parameters as used in Kramer Electronics
products.
Table 5: Communication Parameters
EDID
EDID data is passed between Output 1 and Input 1
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1): #AV 1>1<CR>
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front Panel:
Press and hold Output 1 and
Output 3 simultaneously
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Power cycle the unit while holding in the Factory Reset button, located on
the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000
12 Table of ASCII Codes for Serial Communication (Protocol
3000)
Table 6
and
Table 7
list the ASCII values to switch an input to an output for a
single
VP-4x8AK
machine. For more detailed information, see Protocol 3000
(
Section 14.2
).
Table 6:
VP-4x8AK Video Signal Codes for Protocol 3000
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
IN 1
#V 1>1 CR #V 1>2 CR #V 1>3 CR #V 1>4 CR #V 1>5 CR #V 1>6 CR #V 1>7 CR #V 1>8 CR
IN 2
#V 2>1 CR #V 2>2 CR #V 2>3 CR #V 2>4 CR #V 2>5 CR #V 2>6 CR #V 2>7 CR #V 2>8 CR
IN 3
#V 3>1 CR #V 3>2 CR #V 3>3 CR #V 3>4 CR #V 3>5 CR #V 3>6 CR #V 3>7 CR #V 3>8 CR
IN 4
#V 4>1 CR #V 4>2 CR #V 4>3 CR #V 4>4 CR #V 4>5 CR #V 4>6 CR #V 4>7 CR #V 4>8 CR