Kramer Electronics Ltd.
KDS-EN7, KDS-DEC7
– Protocol 3000
93
Function
Description
Syntax
Response
Parameters/Attributes
Example
LOG-ACTION
Reset events log.
#LOG-ACTION action,period
<CR>
~nn@LOG-ACTION
action,period
<CR><LF>
acton
– one of
1
– start
2
– pause
3
– resume
4 - reset
period - relevant for "start"
1
– keep current
2
– daily
3
– weekly (default)
Reset events log :
#LOG-ACTION 4,2
<CR>
LOG-TAIL?
Get the last “n” lines
of message logs.
NOTE:
Used for
advanced
troubleshooting.
Helps find error root
causes and gets
details not displayed
in the error code
number.
#LOG-TAIL? line_num
<CR>
Get:
~nn@LOG-TAILnn
<CR><LF>
Line content #1
<CR><LF>
Line content #2
<CR><LF>
Etc...
line_num
– Optional, default
line_num is 10
Get the last "2" lines of
message logs:
#LOG-TAIL? 2
<CR>
LOGIN
Set protocol
permission.
NOTE:
The permission
system works only if
security is enabled
with the “SECUR”
command.
LOGIN allows the
user to run
commands with an
End User or
Administrator
permission level.
When the permission
system is enabled,
LOGIN enables
running commands
with the User or
Administrator
permission level
When set, login must
be performed upon
each connection
It is not mandatory to
enable the
permission system in
order to use the
device
In each device, some
connections allow
logging in to different
levels. Some do not
work with security at
all.
Connection may
logout after timeout.
#LOGIN login_level,password
<CR>
~nn@LOGIN
login_level,password
ok
<CR><LF>
or
~nn@LOGIN err
004
<CR><LF>
(if bad password entered)
login_level
– Level of permissions
required (User or Admin)
password
– Predefined password
(by PASS command). Default
password is an empty string
Set the protocol permission
level to Admin (when the
password defined in the
PASS command is 33333):
#LOGIN admin,33333
<CR>
LOGIN?
Get current protocol
permission
level.
NOTE:
The
permission system
works only if security
is enabled with the
“SECUR” command.
For devices that
support security,
LOGIN allows the
user to run
commands with an
End User or
Administrator
permission level.
In each device, some
connections allow
logging in to different
levels. Some do not
work with security at
all.
Connection may
logout after timeout.
#LOGIN?
<CR>
~nn@LOGIN
login_level
<CR><LF>
login_level
– Level of permissions
required (User or Admin)
Get current protocol
permission level:
#LOGIN?
<CR>
LOGOUT
Cancel current
permission
level.
NOTE:
Logs
out from End User or
Administrator
permission levels to
Not Secure.
#LOGOUT
<CR>
~nn@LOGOUT ok
<CR><LF>
#LOGOUT
<CR>
LOGOUT-
TIMEOUT
Set inactivity auto-
logout time.
# LOGOUT-TIMEOUT time
<CR>
~nn@ LOGOUT-TIMEOUT
time
<CR><LF>
time
– minutes of logout time
Set Inactivity auto-logout time
to 10
#LOGOUT-TIMEOUT
10
<CR>
LOGOUT-
TIMEOUT?
Get inactivity auto-
logout time.
#LOGOUT-TIMEOUT?
<CR>
~nn@LOGOUT-TIMEOUT
time
<CR><LF>
time
– minutes of logout time
Get Inactivity auto-logout
time
#LOGOUT-TIMEOUT?
<CR>