2.4 Hazard statements
DANGER
Hazard caused by breakage or fluids spurting out
The connection pipelines must be made pressure-less before any work is
done on the device and prior to removal.
DANGER
Hazard caused by breakage or fluids spurting out
If the device is blocked it acts like a closed gate. The uncontrollable pres-
sure levels that occur in this case can result in damage to the device and
to the upstream system elements. For this reason, use of a pressure limiter
upstream from the device is essential.
It must be taken into consideration that the whole fluid flow must be dis-
charged via the pressure limiting device.
DANGER
Hazard caused by breakage or fluids spurting out
Only connections and pipes approved for the pressure range to be expected
may be used.
The respective manufacturer's regulations must be heeded.
DANGER
Hazard caused by breakage or fluids spurting out
Damaged pipes and hoses must be replaced immediately.
DANGER
Hazard caused by hazardous fluids
When operating the device with hazardous fluids, comply with the safety
datasheets and the regulations on handling these fluids.
Leaks of hazardous transport materials must be collected in such a manner
that no hazards arise for people and the environment.
Always comply with the existing national and international regulations ap-
plicable at the place of installation.
DANGER
Danger posed by voltage
The special safety regulations shall be followed for any work on electrical
installations. This work may only be carried out by a qualified electrician.
Gear type flow meter VC 0,025 ... VC 16
8
2010-07-05 BVC0002EN-D0025420002_01