6.4.1 Standard plug version
●
The electrical connections have to be carried out according to the as-
signment diagram shown below.
To make work more convenient, the plug may be pulled off the housing
cover for cable connection.
The assignment of the terminals for channel 1 and channel 2 influences the
direction of rotation of the measuring unit indicated and thus the sign with
which the measured volume flow is indicated in the evaluation unit.
Tab. 6.3: Assignment standard plug
H1: Status display channel 1
1: 24 Volt (brown)
H2: Status display channel 2
2: Channel 1 (green)
* Cable screw connection
3: Channel 2 (yellow)
** Attachment screw
4: 0 Volt (white)
NOTICE
After installation, the fastening screw (slightly) and the cable screw con-
nection have to be tightened.
Gear type flow meter VC 0,025 ... VC 16
BVC0002EN-D0025420002_01 2010-07-05