![Kracht VC 0,025 Operating Instructions Manual Download Page 62](http://html.mh-extra.com/html/kracht/vc-0-025/vc-0-025_operating-instructions-manual_2000068062.webp)
10 Cleaning
Devices of the series 1, 2, 6, 7 and 8:
Never open these devices yourself
since they can only be reassembled properly for use by specialists.
Devices of the series 3, 4 and 5:
These can be opened and cleaned, taking
appropriate care.
DANGER
Hazard caused by breakage or fluids spurting out
The connection pipelines must be made pressure-less before any work is
done on the device and prior to removal.
DANGER
Hazard caused by hazardous fluids
When operating the device with hazardous fluids, comply with the safety
datasheets and the regulations on handling these fluids.
Leaks of hazardous transport materials must be collected in such a manner
that no hazards arise for people and the environment.
Always comply with the existing national and international regulations ap-
plicable at the place of installation.
DANGER
Hazard caused by hazardous fluids
Before removing and emptying the device, take sufficient protective meas-
ures and wear suitable protective clothing.
Provide sufficiently large collecting tanks.
If necessary, ensure the workstation is sufficiently ventilated.
DANGER
Danger posed by voltage
The special safety regulations shall be followed for any work on electrical
installations. This work may only be carried out by a qualified electrician.
CAUTION
Hazard caused by hot surfaces
At operating temperature above 48 °C the device must be allowed to cool
down first. Danger of scalding.
It must be guaranteed that the connection pipes have been made pressure-
less and the electrical connection is voltage-free.
●
Remove the device (see chapter "
").
●
Empty the measuring device.
Gear type flow meter VC 0,025 ... VC 16
62
2010-07-05 BVC0002EN-D0025420002_01