35
KPS-PA60 • Digital clamp meter
ENG
3.2.7 Resistance
Range
Resolution
Accuracy
400Ω
0,1Ω
±(0,8% of r 3 digits)
4kΩ
0,001kΩ
40kΩ
0,01kΩ
400kΩ
0,1kΩ
4MΩ
0,001MΩ
±(1,2% of r 3 digits)
40MΩ
0,1MΩ
- Open circuit voltage: 0.4V
- Overload protection: 250V DC or rms AC
3.2.8 Diode
Range
Resolution
Accuracy
0,001V
Displaying approximate forward
voltage of diode
- Forward DC current ~ 1mA
- Reversed DC voltage ~ 3.3V
- Overload protection: 250V DC or rms AC
3.2.9 Continuity
Range
Resolution
Accuracy
0,1Ω
Built-in buzzer will sound, if
resistance is lower than 40Ω