32
KPS-PA60 • Digital clamp meter
ENG
Max. input current: 1000A CC
3.2.3 DC Voltage
Range
Resolution
Accuracy
400mV
0,1mV
± (1,0% of r 2 digits)
4V
0,001V
± (0,7% of r 2 digits)
40V
0,01V
400V
0,1V
600V
1V
± (0,8% of r 2 digits)
- Input impedance: 10MΩ
- Max. input voltage: 600V CC
Note:
At small voltage range, unsteady readings will appear before the test leads
contact the circuit. This is normal because the meter is highly sensitive. When
the test leads contact the circuit, the true reading will be shown.
3.2.4 AC Voltage
Range
Resolution
Accuracy
4V
0,001V
± (0,8% of r 3 digits)
40V
0,01V
400V
0,1V
750V
1V
± (1,0% of r 4 digits)
- Input impedance: 10MΩ
- Max. input voltage: 600V CA rms
- Frequency range: 40 ~ 400Hz