KPS-PA60 • Digital clamp meter
ENG
3.2.11 Capacitance
Range
Resolution
Accuracy
40nF
0,01nF
±(4,0% of r 5 digits)
400nF
0,1nF
4μF
0,001nF
40μF
0,01μF
400μF
0,1μF
4000μF
1μF
- Overload protection: 250V DC or rms AC
4. OPERATION INSTRUCTION
4.1 Holding readings
•
Press the “HOLD/B.L” button to hold the readings while taking measurement
and the value on the display will be held.
•
Press the “HOLD/B.L” button again to release the reading hold function.
4.2 Switching REL
1) REL key is the relative value measurement communication transmission key
that acts with trigger. Press this key will enter intom the relative value meas-
urement mode. The system will save the display value in the memory as the
reference value. When doing the measurement later, the display value will be
the difference value that the entry value deducts the reference value.
2) Press RELΔ key will enter into the Manual Measurement Mode automati
-
cally.
3) In RELΔ, measurement status, press the key again, the RELΔ function will
be relocked.
4) Press the key in HOLD status, HOLD function will be cancelled. The system
will save the display value in the memory as the reference value. When doing
the measurement later, the display value is the difference that the entry value
deducts the reference value.
5) Press FUNC Key or use Mode Switch will cancel RELΔ measurement mode,
and go back to the normal mode (el símbolo RELΔ will disappear in the LCD).