5-14
4.
-V2 CLEAN BIAS
Use a digital multimeter and set to DC Voltage scale. Connect the meter’s
red probe into the High Voltage Supply –V2, and then connect the black probe
into the Case GND (See Fig.5-12). Turn on CLEAN BIAS under ENGINE
CHECK selection, and then adjust High Voltage Supply VR701 (See Fig.5-13).
Turn VR701 clockwise to increase the voltage. Turn VR701 counterclockwise
to decrease the voltage. Adjust VR701 to –275V.
Fig.5-12
Fig.5-13
Summary of Contents for KP3828 Series
Page 4: ...Chapter 1 Overview ...
Page 5: ...1 1 1 1 External View External View ...
Page 17: ...Chapter 2 Principles ...
Page 40: ...Chapter 3 Installation ...
Page 47: ...3 7 Step 13 Remove the nut from the drum shaft Fig 3 7 Nut ...
Page 59: ...3 19 Fig 3 19 AC power terminal box AC cable Breaker Turn on AC power terminal box KMPU board ...
Page 65: ...Chapter 4 Electrical System ...
Page 72: ...Chapter 5 Adjustments ...
Page 88: ...5 16 Fig 5 16 Fig 5 17 ...
Page 90: ...Chapter 6 Periodic Maintenance ...
Page 96: ...6 6 6 3 3 Developing Unit Hopper Area Fig 6 3 6 3 4 Cleaning Unit Area Fig 6 4 Cleaning unit ...
Page 105: ...6 15 2 Wipe the drum surface with the special cloth Fig 6 14 Drum Special cloth ...
Page 113: ...Chapter 7 Parts Replacement ...
Page 172: ...Chapter 8 Troubleshooting ...
Page 230: ...Appendix I KMPU Circuit Diagram ...