7-27
7-2-17 Fuser Unit
Loosening the thumbscrews on the holder plates at the right and left sides
can pull out the fuser unit. Make sure to make room below the fuser unit
by turning the green lever to the left to lower the transport surface.
Fig.7-43
WARNING
Be careful of handling the fuser unit. The unit reaches high temperatures
immediately after operation (over 141
℃
when temperature fuse is blown).
Also, never touch the cover glass with your hands.
This fuser unit has the following replaceable parts:
(1) Xenon lamp
(2) Fuse set
(3) Fuser cover glass
(4) Xenon lamp trigger coil unit
(5)
HV connector for fuser unit
Fuser unit
Green lever
Thumbscrew on holder plate