8-8
Bring the positive lead of a digital
multimeter in contact with pin 31 of
CN6 of the KMPU board and the
negative lead in contact with SG (pin
32), and measure the voltage.
If normal, the voltage will be
approximately 0 V when upper sensor
is blocked and will be approximately 5
V when upper sensor is not blocked.
8
Is the position of
transfer unit upper limit
sensor appropriate?
If YES, go to 9.
If NO, adjust the
positions of the
sensor and the
blind.
Mount the transfer elevator motor and
transfer unit upper limit sensor to the
main body, set the transfer unit, and
then check the following.
Bring the positive lead of a digital
multimeter in contact with pin 31 of
CN6 of the KMPU board and the
negative lead in contact with SG
(pin32), and measure the voltage.
If normal, the voltage will be
approximately 0 V when the transfer
position is raised to the upper limit and
will be approximately 5 V when the
transfer position is lowered to the lower
limit.
9
Replace the KMPU
board.
Summary of Contents for KP3828 Series
Page 4: ...Chapter 1 Overview ...
Page 5: ...1 1 1 1 External View External View ...
Page 17: ...Chapter 2 Principles ...
Page 40: ...Chapter 3 Installation ...
Page 47: ...3 7 Step 13 Remove the nut from the drum shaft Fig 3 7 Nut ...
Page 59: ...3 19 Fig 3 19 AC power terminal box AC cable Breaker Turn on AC power terminal box KMPU board ...
Page 65: ...Chapter 4 Electrical System ...
Page 72: ...Chapter 5 Adjustments ...
Page 88: ...5 16 Fig 5 16 Fig 5 17 ...
Page 90: ...Chapter 6 Periodic Maintenance ...
Page 96: ...6 6 6 3 3 Developing Unit Hopper Area Fig 6 3 6 3 4 Cleaning Unit Area Fig 6 4 Cleaning unit ...
Page 105: ...6 15 2 Wipe the drum surface with the special cloth Fig 6 14 Drum Special cloth ...
Page 113: ...Chapter 7 Parts Replacement ...
Page 172: ...Chapter 8 Troubleshooting ...
Page 230: ...Appendix I KMPU Circuit Diagram ...