7-22
7-2-16 Transport Belt
When replacing the transport belt, the transport unit must be turned
upside-down to remove the base conveyor. When turning the unit
upside-down, be sure to put a rest underneath it to protect the protruding
tips of the sensor levers. Also, be careful when handling the lever.
1. Remove the suction fan and disconnect the sensor connectors.
Fig.7-33
2. Restore the transport unit to its original position. Remove the screws
securing the output guide and then remove the output guide.
Fig.7-34
Connectors
Suction fan
Screws
Output guide
Summary of Contents for KP3828 Series