8-37
8-4 Causes of and Remedies for Errors
1. Toner odor
Re
m
arks
Replace after 200,000
(8.5”) pages.
Execute th
e “Device
ON” comm
and.
Abnor
m
al lamp house
tem
perature or paper jam
at the tran
sp
ort sec
tion
has occurred
.
Re
m
edy
Insta
ll the f
ilter a
t the cor
rect
position.
Replace th
e filter with a new one.
Replace th
e filter with a new one.
Check the power supply system
for the air filter b
lower (electrical
counterm
easures).
Insta
ll the fuser cove
r gla
ss. If the
cover glass is broken, replace the
glass.
Cause
The air f
ilte
r is no
t
insta
lled.
The frame (pack
ing s
ection
)
of the air filter is s
tra
ined
.
The air filte
r has reached
the end of
its lif
e.
The air filte
r blower is
stopped.
The fuser cover glass is not
installed or is broken.
Phenom
enon
1.
Toner odor is em
itted from the
air filter b
lo
w
er outlet.
2.
Toner odor is em
itted during
fusing. (Air filter b
lower)
3.
Toner odor is em
itted from the
fuser exit blower or from the
fuser unit upper fan.
Summary of Contents for KP3828 Series
Page 4: ...Chapter 1 Overview ...
Page 5: ...1 1 1 1 External View External View ...
Page 17: ...Chapter 2 Principles ...
Page 40: ...Chapter 3 Installation ...
Page 47: ...3 7 Step 13 Remove the nut from the drum shaft Fig 3 7 Nut ...
Page 59: ...3 19 Fig 3 19 AC power terminal box AC cable Breaker Turn on AC power terminal box KMPU board ...
Page 65: ...Chapter 4 Electrical System ...
Page 72: ...Chapter 5 Adjustments ...
Page 88: ...5 16 Fig 5 16 Fig 5 17 ...
Page 90: ...Chapter 6 Periodic Maintenance ...
Page 96: ...6 6 6 3 3 Developing Unit Hopper Area Fig 6 3 6 3 4 Cleaning Unit Area Fig 6 4 Cleaning unit ...
Page 105: ...6 15 2 Wipe the drum surface with the special cloth Fig 6 14 Drum Special cloth ...
Page 113: ...Chapter 7 Parts Replacement ...
Page 172: ...Chapter 8 Troubleshooting ...
Page 230: ...Appendix I KMPU Circuit Diagram ...