NOTICE:
Surface temperature of adjacent walls and mantels become hot during operation.
Walls and mantels above the firebox may become too hot to touch. If installed properly, these
temperatures meet the requirement of the national product standard. Follow all minimum
clearances shown in this manual.
NOTICE:
If your installation does not meet the minimum clearances shown, you must do one of
the following: Operate the logs with the flue damper open only. Raise the mantel to an
acceptable height.
FLOOR CLEARANCES
a) If installing appliance on floor level, you must maintain the minimum distance of 14
in. to combustibles (see Fig. 7).
b) If combustible materials are less than 14 in. to the fireplace, you must install
appliance at least 5 in. above the combustible flooring (see Fig. 8).
Fig. 7- Minimum fireplace
clearances if installed at floor level
Combustible
Material
14 in.
Min
Noncombustible
Material
Fig. 8 - Minimum fireplace clearances
above combustible flooring
Combustible
Material
5 in.
Min
Hearth
Fig. 9 - Attach Damper to Fireplace
Damper
Damper
Clamp
Damper