8.4 #SF36-500 Log Set Installation
CAUTION: Do not place logs directly over burner portholes. Improper
log placement may affect flame appearance and cause excessive soot
to build upon the logs and glass.
•
If converting to propane, complete the conversion before
installing the log set. Follow the conversion instructions included
with the kit.
•
Log numbers are located on the bottom of each log. Refer to the
following instructions and illustrations for proper log placement.
1. Position the ember panel in front of the burner assembly.
2. Position the holes in the bottom of log SF36-1 onto the (2)
mounting pins at the back of the burner assembly.
3. Position the holes in the bottom of SF36-2 and SF36-3 onto the
corresponding mounting pins on the burner.
4. Position the hole in the bottom of log SF36-4 onto the
corresponding mounting pin on the burner.
5. Position the holes in the bottom of log SF36-5 onto the
corresponding (2) mounting pins on the burner.
6. Position log SF36-6 as shown. Position SF36-6 with the notch in
SF36-2, and align the hole on the bottom with the pin on the left
of SF36-1. Set log SF36-6 into position.
7. Position log SF36-8 as shown. Position SF36-8 with the notch in
SF36-3, and align the hole on the bottom with the pin on the
right of SF36-1. Set log SF36-8 into position.
8. Position logs SF36-9, SF36-7, and SF36-10 as shown.
9. Use a steel or stiff bristle nylon brush to distribute rock wool
embers onto logs and burner.
FIGURE 8.3
Completed Install
FIGURE 8.2
Base Logs