34
FIREPLACE SET UP
9.4 Control Board Removal
and Installation
WARNING: If burner and/or pilot have been burning,
use appropriate protection to avoid burns or damage
to personal property before removing any components.
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING
GASKET (LOCATED UNDER THE CONTROL BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water,
whether field or factory made.
9.4.1 Control Board Removal
1. Disconnect electrical power.
2. Locate the manual valve installed by your qualified service
technician.
3. Turn the manual valve clockwise to the OFF position.
4. Remove the safety barrier and glass frame assembly.
5. Remove glass media and media dam.
6. Remove burner cover (10) screws.
7. Remove burner venturi housing. Remove burner tube from
mounting cradles.
8. Remove (2) nuts securing light bar to control board. Carefully
move light bar backwards far enough to clear board.
9. Remove (8) screws securing control board. Lift the control
board out of firebox, being careful not to damage sealing
gasket lying underneath.
9.4.2 Control Board Installation
1. Place control board in firebox, aligning holes in the board to
the holes in the firebox floor. VERIFY SEALING GASKET IS
IN PLACE.
2. Secure the control board to the firebox using (8) screws
previously removed.
3. Reinstall light bar onto control board, secure with (2) nuts
previously removed.
4. Reinstall burner. Position the burner venturi over burner
orifice, aligning the burner tube with mounting cradles on
control board.
5. Reinstall burner venturi housing.
6. Reinstall burner cover, aligning holes in cover to
corresponding holes in burner tube mounting cradles.
Secure with (10) screws previously removed.
7. Reinstall the media dam.
8. Reinstall glass media, being careful not to block pilot.
9. Reinstall the glass frame assembly and safety barrier.
10. Turn the manual valve counterclockwise to the ON position.
11. Reconnect electrical power.
12. Verify proper glass media placement, operation of fireplace,
and any electrical components.
Figure 9.3, Control Board Removal and Installation
(10) SCREWS SECURING BURNER COVER
(2) NUTS SECURING LIGHT BAR
(8) SCREWS SECURING CONTROL BOARD