background image

FRAMING 

15

3.7  Vent Termination Framing

IMPORTANT: Vent cap location must be in compliance with 
Section 7.2 Minimum Termination Clearances on page 25.
WARNING: DO NOT RECESS THE VENT CAP INTO WALL OR 
SIDING. 

3.7.1  Vertical Terminations

CAUTION: Cold air transfer area. The surround fireplace chase 
must comply with all clearances as outlined in this manual, 
and be constructed in compliance with local building codes. 
Outside walls should be insulated to prevent cold air from 
entering room. 

•  Follow vent pipe manufacturer’s installation instructions for 

vertical terminations. 

•  A minimum of 1 in (25 mm) clearance on all sides of the 

vertical vent pipe must be maintained.

•  Attic insulation shields may be insulated using unfaced 

insulation products listed as non-combustible per ASTM E 
136.

3.7.2  Horizontal Terminations

IMPORTANT: Horizontal vent sections require 1/4 in (6 mm) rise 
for every 12 in (305 mm) of travel. 
NOTE: Wall thimble products that comply with the required 1 
in (25 mm) clearance to combustibles must be installed for all 
horizontal vent runs that pass through interior or exterior walls. 
These wall thimble products may be insulated using unfaced 
insulation products listed as noncombustible per ASTM E 136.

1.  Measure from floor level of the fireplace to the center of 

where the vent pipe will penetrate the wall. Elbows listed 
with approved vent systems for this appliance vary in vertical 
length. Please consult the vent manufacturer’s instructions 
to determine the elbow dimension used for installation. 
Adjust the wall pass-through rough opening dimensions as 
necessary to maintain clearance requirements.

2.  Cut and frame an opening in the wall to allow the vent system 

to run level through the wall pass-through. 

3.  Follow the vent pipe manufacturer’s installation instructions 

for vent installation. 

Figure 3.6, Minimum Horizontal Termination Framing

19”

(483mm)

35

5⁄8

(905mm)

47

5⁄8

(1210mm)

43”

(1092mm)

19”

(483mm)

19”

(483mm)

MINIMUM HORIZONTAL RIGID VENT PIPE TERMINATION 

NATURAL GAS AND LP GAS

MINIMUM HORIZONTAL RIGID VENT PIPE TERMINATION 

LP GAS

MINIMUM HORIZONTAL FLEX VENT PIPE TERMINATION 

NATURAL GAS AND LP GAS 

Summary of Contents for SLA-36

Page 1: ...where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit...

Page 2: ......

Page 3: ...safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeowner...

Page 4: ......

Page 5: ...ON 23 6 1 Gas Conversion sold separately 23 6 2 Gas Line Installation 23 7 0 TERMINATION LOCATIONS 24 7 1 Vertical Vent Cap Termination 24 7 2 Minimum Termination Clearances 25 8 0 VENTING 26 8 1 Appr...

Page 6: ......

Page 7: ...he above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the bu...

Page 8: ...Btu h 4 98 kW 17 000 Btu h 4 98 kW Manifold Pressure High 3 8 WC 0 95 kPa 11 WC 2 74 kPa Manifold Pressure Low 1 1 WC 0 27 kPa 2 9 WC 72 kPa Orifice Size DMS 37 0625 2 2 1 Altitude Adjustment This ap...

Page 9: ...m 81 16 204mm 1513 16 402mm 48 1238mm 61 8 155mm 51 8 130mm 365 8 930mm 7 198mm 2813 16 732mm 39 997mm 435 8 1108mm 48 1238mm 77 8 200mm 18 457mm 513 16 148mm 43 16 107mm 4 121mm TOP FRONT LEFT SIDE R...

Page 10: ...4 Optional Trim Kit Assembly SL36 FTK on page 22 2 4 1 Safety Barrier Installation 1 Center the screen front over the glass frame assembly allowing the screen front s mounting brackets to fit inside t...

Page 11: ...d sheetrock et cetera in this zone Top stand off brackets must be formed and attached prior to positioning fireplace into framed opening 1 Remove and save the 4 screws securing the top stand off heat...

Page 12: ...learances to Combustible Material From appliance top stand offs 0 in 0 mm From appliance left and right side stand offs 0 in 0 mm From appliance back stand offs 0 in 0 mm From appliance bottom stand o...

Page 13: ...nce requirements This fireplace may be elevated off the floor as shown below provided it is properly supported by framing materials and maintains ceiling clearances If masonry is to be used optional p...

Page 14: ...tible material may be used 3 6 Recess Construction WARNING All clearances to venting must be maintained Mounting a television above a fireplace has become a common practice Television surface temperat...

Page 15: ...uired 1 in 25 mm clearance to combustibles must be installed for all horizontal vent runs that pass through interior or exterior walls These wall thimble products may be insulated using unfaced insula...

Page 16: ...etal screws 1 Register cover with screws 4 Sheet rock screws 1 Duct collar 3 Flange nuts 1 Fan assembly 1 Strapping cord 1 Fan housing cover plate 3 Wire nuts 1 Speed control mounting bracket 2 Fan wi...

Page 17: ...allow for sheetrock installation 5 Secure the mounting bracket to framing with the provided 4 sheetrock screws 6 Install the junction box on the wall at desired location The junction box is used to h...

Page 18: ...speed control through the mounting bracket Secure with the mounting nut 4 Secure mounting bracket to the junction box with the 2 screws provided 5 Center the register cover over the fan housing cover...

Page 19: ...fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flange until parallel with fireplace face Do not bend to...

Page 20: ...nents To secure material to this area use a silicone sealant that has a 300 F 149 C continuous exposure rating It is acceptable to pre drill holes and to use self tapping screws prior to attach the no...

Page 21: ...E MATERIAL ONLY COMBUSTIBLE MATERIAL ALLOWED COMBUSTIBLE MATERIAL ALLOWED LOWER COVER PANEL COMBUSTIBLE MATERIAL ALLOWED NO SCREWS ABOVE FRAMING BOTTOM 19mm COMBUSTIBLE MATERIAL ALLOWED NON COMBUSTIBL...

Page 22: ...s above and 5 holes below the fireplace opening and 3 holes on each side 2 Align the top and bottom trim panels with the pre drilled holes on the fireplace face Position the flange on the trim panel a...

Page 23: ...ssures in excess of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A...

Page 24: ...ver 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Ov...

Page 25: ...r inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L Clearance above...

Page 26: ...red 1 in 25 mm clearance to combustibles must be installed for all horizontal vent runs that pass through interior or exterior walls These wall thimble products may be insulated using unfaced insulati...

Page 27: ...5 x 8 Vent Configurations Table 8 1 NG LPG Minimum Maximum Vertical Terminations Minimum 5 x 8 Vertical Length Maximum 5 x 8 Vertical Length 2 ft 610 mm 50 ft 15 2 m 8 5 2 4 x 65 8 Reducer Vent Config...

Page 28: ...5 x 8 Horizontal Run 90 elbow 9 in 229 mm 4 ft 1219 mm Table 8 4 NG Max Vertical Max Horizontal Combination Maximum 5 x 8 Vertical Rise Maximum 5 x 8 Horizontal Run Total 5 x 8 Length 20 ft 6 m 20 ft...

Page 29: ...mm Table 8 6 LPG Max Vertical Max Horizontal Combination Maximum 5 x 8 Vertical Rise Maximum 5 x 8 Horizontal Run Total 5 x 8 Length 20 ft 6 m 20 ft 6 m 40 ft 12 2 m Maximum number of 90 elbows 5 Fig...

Page 30: ...229 mm 3 ft 914 mm Table 8 8 NG LPG Max Vertical Max Horizontal Combination Maximum 4 x 65 8 Vertical Rise Maximum 4 x 65 8 Horizontal Run Total 4 x 65 8 Length 20 ft 6 m 20 ft 6 m 40 ft 12 2 m Maxim...

Page 31: ...d of exterior sealant around outer edge of termination box A placing assembly through the wall pass through in exterior wall Place screws through the four holes B securing it in place 4 Form the 5 8 f...

Page 32: ...s out and up to secure assembly bottom 3 Reinstall component upper heat shield secure with wing nuts re attach component board magnet to upper heat shield 4 Reinstall valve access cover using screws p...

Page 33: ...on 1 Remove glass media from its packaging The glass media may be cleaned prior to installation See section 9 3 3 below 2 Install 10 lbs 4 5 kg of crushed glass onto burner assembly and pilot shield 3...

Page 34: ...the control board out of firebox being careful not to damage sealing gasket lying underneath 9 4 2 Control Board Installation 1 Place control board in firebox aligning holes in the board to the holes...

Page 35: ...t cut or remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local...

Page 36: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Page 37: ...osition for remote control operation of the main burner and fireplace features 11 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Page 38: ...y 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After approximat...

Page 39: ...ng pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD scre...

Page 40: ...can be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature...

Page 41: ...ode Fan s will operate at previous setting There is no delay in start up or stop time 11 8 9 Accent Light Kit The light intensity can be adjusted through 6 levels 1 Press the mode key to index to the...

Page 42: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Page 43: ...me but may produce soot on the glass Opening the air shutter will cause a short blue flame that may lift off the burner 12 2 1 1 Venturi Opening Adjustment IMPORTANT Slight adjustments to the venturi...

Page 44: ...gas supply and call a qualified service technician 12 2 2 1 Restrictor Plate Installation 1 Remove the safety barrier and the glass frame assembly 2 Remove 2 screws securing termination access panel...

Page 45: ...gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a low line pr...

Page 46: ...to be opened slightly to allow more air into the gas mix Refer to Section 12 2 1 Burner Venturi on page 43 Incorrect vent cap installation Adjust if necessary Vent cap blockage Remove debris if necess...

Page 47: ...e sealed and require no oiling 14 3 Vent System NOTE If the vent air intake system is disassembled for any reason reinstall per instructions provided with installation Section 8 0 Venting on page 26 P...

Page 48: ...ness Assembly 700 653 LPG Burner Orifice 0625 700 625 Pilot Assembly NG 700 596 Conversion Kit NG NCK SL36 SP Pilot Assembly LPG 700 596 1 Conversion Kit LPG LCK SL36 SP Transmitter Remote Control 700...

Page 49: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Page 50: ......

Page 51: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Reviews: