18
CONVERSION KIT INSTRUCTIONS
FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
WARNING
Burner tube adjustable venturi positioning should only be performed by a qualified professional service technician.
Figure 18a
Lazy yellow flames
- ideal
Short blue flames
venturi open too far
Dark orange flames / black tips
Venturi closed too far
Excessive burner media
Lifting (ghosting) flames
Improper Venting
Gas pressure too high
Correct pilot flame
Figure 18b
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
VENTURI POSITION
FLAME COLOR
VENTURI ADJUSTMENT
Closed too far
Dark orange flame with black tips
Open venturi setting slightly
Open too far
Blue flames
Close venturi setting slightly
TO ADJUST VENTURI:
Figure 18c
IMPORTANT
SLIGHT ADJUSTM ENTS TO BURNER VENTURI OP ENING CREATE DRAMATIC RESULTS. ADJUST AT SLIGHT
INCREMENTS UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES
AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
BURNER VENTURI
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
LP (PROPANE) GAS
1/16” (2mm) OPEN
5/8” (16mm) OPEN
1. Remove screen front and glass frame assembly.
2. Remove glass media.
3. Remove burner assembly.
4. Loosen screw on burner venturi and adjust as necessary. Tighten screws.
5. Reinstall all components previously removed.
6. Light fireplace and wait 15 minutes before determining if any further adjustments are
needed.