
#600-TLKMV Light Kit
SECTION 9
ELECTRICAL INFORMATION
#CLW-50-MV
R.1 October 2021
56
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
9.2 #600-TLKMV Light Kit
CAUTION: Disconnect all electrical power from the fireplace before
performing this task.
IMPORTANT: Installation of an external on/off switch or dimmer switch
is required for operational control of the electrical power supply to
the light kit. Consult your qualified electrician for the best method
to accomplish this, especially if installing in combination with the
optional fan #SL42-028MV.
NOTE: To avoid damage and prolong the life of the halogen bulbs,
never touch with bare hands. Always use a soft cloth when handling.
Refer to
for the installation steps outlined below.
1. Remove the safety screen, gas valve access cover, and glass
frame assembly.
2. Remove the light kit covers and roped glass, (4) screws total.
Save screws.
3. Install (2) halogen bulbs (included with this kit) into lamp bases.
4. Locate the wiring in the control compartment. Complete wiring.
5. Reinstall light kit cover and roped glass with (4) screws
previously removed.
6. Reinstall glass frame assembly, gas valve access cover, and
safety screen.
9.2.1 Replacing Bulbs
1. Remove the safety screen, gas valve access cover, and glass
frame assembly.
2. Remove the light kit cover and roped glass, (4) screws. See
Save screws.
3. Remove (2) halogen bulbs.
4. Using a soft cloth or gloves, install (2) halogen bulbs into
lamp bases.
5. Reinstall light kit cover and roped glass with (4) screws
previously removed.
6. Reinstall glass frame assembly, gas valve access cover, and
safety screen.
Install (2) halogen bulbs
Reinstall light kit cover and roped glass (4) screws total
FIGURE 9.3
Light Kit Installation
FIGURE 9.4
Bulb Replacement