2 oil ports located on the top of the motor, one near the end and one near
the fan housing as shown in Figure 22. There may be rubber plugs in one
or both of these oil ports. These plugs must be removed prior to and
replaced after oiling. Place a few drops of light oil, such as sewing
machine oil, in each port.
Figure 21. Bolts and screws securing the
right side cover panel to the stove.
Figure 22. Oil ports on a circulation fan
BOLTS
SCREWS
6. Perform weekly maintenance.
Weekly or more frequently if needed:
1. Pull and push the heat exchanger tube cleaning rod which is located in the
center, above the door (See Figure 23) when the stove is cold. This will
remove the ash deposits on the heat exchanger tubes. The removed ash
will fall on the top heat shield, located in the burn chamber.
Figure 23. Tube scraper rod to clean the heat exchanger pipes.
Tube scraper rod for
heat exchanger