82
Efficiency
Max.Efficiency
>98.2%
PV Input
Max. PV input power(W)
Max. PV input voltage(V)
1000
MPP Operation Voltage Range(V)
180-900
Max. number of PV strings per MPPT
2PCS/(1+1)PCS
Max. PV input current(A)
12.5/12.5
Short-circuit current of PV input(A)
13.5/13.5
Start up voltage(V)
180
Battery
Max Input/Output Voltage(V)
700
Operating Voltage Range(V)
180-700
Max Charge/Discharge Current(A)
50/50
Max Input/Output Power(W)
12000/12000
Battery Type
Li-ion/Lead-acid
AC Input and Output
Rated Power(W)
12000
Max. Apparent AC Power(VA)
12000
Nominal AC Voltage(Vac)
380,3L/N/PE
AC Power Frequency(Hz)
50/60
Max. AC Output Current(A)
18
Rated Current Output(A)
18
Power Factor Range
~1 (Adjustable from 0.8 leading to 0.8 lagging)
OutputTHDi(@Nominal Output)
<3%
Off-Grid AC Output(Back-up AC
Output )
Rated Output Power(W)
12000
Max. Apparent AC Output Power(VA)
12000
Nominal AC Output Voltage(Vac)
380,3L/N/PE
AC Power Frequency(Hz)
50/60
Max. AC Output Current(A)
18
Genaral Data
Operating Temperature Range
-25
℃
…
+60
℃
(>45
12-20KW Three-Phase Hybrid Inverter
Model
EST-12KH
EST-15KH
EST-17KH
EST-20KH
℃
derating)
Operating Altitude(m)
<4000
Noise(dB)
<45
Topology
Transformerless
Cooling Method
Intelligent Fan
Ingress Protection Rating
IP65
Relative Humidity
0-100%, no condensation
DC Connection Type
MC/Amphenol/Phoenix
AC Connection Type
Plug-in Connector
Display
LCD
Communication With Portal
RS485 (WiFi/GPRS Optinal)
Communication With BMS
CAN
Communication With Meter
RS485
Mounting Method
Wall-mounting bracket
Dimensions (W*H*D)(mm)
505*630*220
Weight(Kg)
26
Certification
Safety
IEC62109-1/-2
EMC
EN61000-6-1/-2/-3,IEC61000
On-Grid standard
AS4777.2,NRS097-2-1:2017
Country of origin
Made in China
15600
19500
22100
26000
2PCS/(2+1)PCS
4PCS/(2+2)PCS
12.5/23
23/23
13.5/25
25/25
15000/15000 17000/17000 20000/20000
15000
17000
20000
15000
17000
20000
22
25
31
22
25
31
15000
17000
20000
15000
17000
20000
22
25
31
27
27
28
Summary of Contents for KY-EST06KH
Page 1: ...1 User Manual 3 Phase Hybrid Inverter KY EST06KH KY EST20KH V1 0...
Page 10: ...10 Dimensions KY EST06 10KH unit mm Dimensions KY EST12 20KH unit mm...
Page 12: ...12 Fig1 5 Three phase Meter Dimension unit mm...
Page 15: ...15 Each successive press of the button selects a new parameter...