Failure
Cause
Remedy
The display shows ‘burner sensor
short-circuit’ message
³
Incorrect burner plate sensor
installation
³
Burner plate outlet damage
³
Burner duct damage
³
Check sensor installation
³
Check plate outlet
³
Check burner duct
The display shows ‘heat exchanger
overheating’ or ‘STB open’ message
³
Incorrect boiler temperature sensor
installation
³
Boiler temperature sensor failure
³
No heat removal
³
STB safety temperature limiter
³
Check correct sensor position
³
Check the sensor connection in the
control
³
Boiler pump failure
³
Repair or replace control
The display shows ‘burner overheating’
message
³
Incorrect sensor installation
³
Feeder sensor failure
³
Fouled burner grate - sinter on the
grate
³
Check sensor installation
³
Replace feeder sensor
³
Clean burner grate
No indications on the display
³
No power supply
³
Incorrect connection of control
system plugs and cables
³
High control humidity
³
Display failure
³
Check power supply connections
³
Check control plugs
and connectors
³
Control replacement / repair
Control system button(s) not working
³
Control panel failure
³
Control system repair
Automatic fuel ignition not working -
‘No fire/fuel’ message
³
Incorrect settings of heating
element, heating time and fire test
³
Incorrect heating element
connection
³
Heating element hot air outlet
blocked
³
Heating element failure
³
Flame sensor fouling/failure
³
Flame sensor opening at the rear
grate wall fouled
³
Change settings
³
Check heating element plugs and
cables (with connectors)
³
Clean igniter opening
³
High fuel moisture content
³
Replace heating element
³
Replace or clean the flame sensor
³
Clean flame sensor opening
Black smoke in the combustion chamber
Not combusted fuel in the ash pan
³
Incorrect air volume
³
Incorrect feed and pause time for
specific power
³
Reduce air volume, check feed and
pause time (burner power too high)
Summary of Contents for Mini Bio
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 46: ......
Page 48: ......
Page 86: ......
Page 88: ......
Page 126: ......
Page 127: ...Twin Bio PLV 09 13 Twin Bio PLV 09 13 R U PN EN303 5 2 0 1 2 PN EN30 3 5 2 0 1 2...
Page 128: ......
Page 130: ......
Page 154: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 154 6 154 ON 6...
Page 155: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 155 7 155 7...
Page 165: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 165 13 165 a STB STB...
Page 166: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 166 13 166 a...
Page 168: ......
Page 170: ......
Page 208: ......
Page 210: ......
Page 247: ......
Page 248: ......