61
Mini Bio
and
Mini Bio Luxury
User Manual - ENGV 08.15
Experts in heating
4.
Mini
Bio
/
Mini
Bio
Luxury
boi
l
er
design
(as
a
co
m
p
l
e
t
e
h
ea
t
ing
device)
4.G Wiring system
General guidelines on the wiring systems of a boiler control, a boiler
and its accessories:
1. A 230 V/50 Hz power system conforming to local standards and
regulations must be available in the boiler room.
2. The wiring system must be terminated with a plug-in socket and
a protective conductor contact.
3. The wiring system must be installed in accordance with the
electrical diagram and local regulations concerning electrical
safety.
4. The device (boiler/control system) must be connected to an
individual system with an overcurrent protection and a residual
current device.
NO OTHER EQUIPMENT MAY BE CONNECTED TO THE
BOILER’S ELECTRICAL SYSTEM.
5. The wiring system may be installed and repaired by authorised
personnel only.
6. Disconnect the power supply before servicing.
7. The boiler temperature sensor must be installed and secured in
a submersible sleeve in the water section. The remaining cable
must be coiled and laid in the external boiler casing or other
safe location (secured against sliding off from the sleeve).
8. The cables should not be bent or broken and the insulation
should not be damaged.
9. Do not allow water, moisture, dust and dirt inside the device,
otherwise it may result in short-circuit, electric shock, fire or
damage.
10. Ensure proper ventilation of the device (control) and free air flow
to the vents and air circulation around the device.
11. The electrical equipment (control, distribution board, burner and
sensors) are intended for indoor installation.
4.H Mini Bio/Mini Bio Luxury control system
A detailed description of the control system functions is included
in the Platinum Bio control User Manual.
WARNING!!! Using the socket without
a protective conductor contact may
result in electric shock!
Platinum Bio control for Mini Bio boiler
Platinum Bio Slim control for Mini Bio Luxury boiler
Summary of Contents for Mini Bio
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 46: ......
Page 48: ......
Page 86: ......
Page 88: ......
Page 126: ......
Page 127: ...Twin Bio PLV 09 13 Twin Bio PLV 09 13 R U PN EN303 5 2 0 1 2 PN EN30 3 5 2 0 1 2...
Page 128: ......
Page 130: ......
Page 154: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 154 6 154 ON 6...
Page 155: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 155 7 155 7...
Page 165: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 165 13 165 a STB STB...
Page 166: ...Sp cialistes en chauffage Mini Bio Mini Bio Luxury RUV 08 15 166 13 166 a...
Page 168: ......
Page 170: ......
Page 208: ......
Page 210: ......
Page 247: ......
Page 248: ......