Xpac
Installation Manual -- Version 5.1 (5/08)
G-8
REXA
Electraulic Actuators & Drives
4. Loosen the tube fitting where it attaches to the auxiliary
cylinder.
5. Continue filling and purging until clear oil drains out of
the loosened fitting.
6. Tighten the loose fitting.
7. Continue adding oil until the auxiliary cylinder rod ex-
tends to the relevant dimension stated in section G.3.1,
Oil Level Check.
8. Allow the unit to perform a recharge cycle (G.1.3) and
check oil level.