![Kortho 814532 Manual Download Page 33](http://html1.mh-extra.com/html/kortho/814532/814532_manual_1999035033.webp)
OPERATION
H215 AE
Rev.: 10
kortho
Hot Quick Coder-D
6-7
When
this
parameter
is
set,
the
busy
signal
is
set
from
the
moment
the
control
box
is
powered
on
until
the
printer
temperature
(
er
pr
T
int
)
has
reached
a
value
equal
or
greater
than
SET
TEMP
(
set
T
)
minus
READY
TEMP
(
ready
T
).
ready
set
er
pr
T
T
T
−
≥
int
The
preferred
READY
TEMP
values
are
OFF
and
-0°
C,
the
other
values
are
meant
for
special
environments.
While
the
busy
signal
is
active,
the
printer
ignores
trigger
signals
and
will
not
print.
This
parameter
is
usual
used
with
automatically
controlled
packaging
machines.
It
prevents
printing
until
the
printer
has
reached
(nearly)
the
desired
temperature.
Note:
The
busy
signal
status
is
not
displayed
when
the
busy
signal
is
set
by
the
READY
TEMP
parameter,
only
the
output
is
set.
(Reminder:
The
busy
signal
status
is
displayed
as
the
P
‐
icon
when
the
printer
is
printing)
Press
button:
UP
ARROW
to
increase
the
parameter
value.
DOWN
ARROW
to
decrease
the
parameter
value.
LEFT
ARROW
to
shift
to
the
EXT.BUSY
parameter.
RIGHT
ARROW
to
shift
to
the
POWER
ON
parameter.
STOP
to
return
to
the
STOP
MODE
MENU
and
stop
printing.
6.3.10 Power
on
This
parameter
is
only
accessible
from
the
READY
TEMP
parameter.
Fig.
6.15
POWER
ON
parameter.
The
POWER
ON
parameter
sets
the
mode
at
which
the
control
box
will
start
after
power
on.
This
parameter
has
two
possible
settings,
STOP
and
RUN.
The
current
parameter
value
is
represented
by
****.
This
parameter
is
usual
used
with
automatically
controlled
packaging
machines.
Press
button:
UP
ARROW
to
toggle
the
parameter
to
the
RUN
value.
DOWN
ARROW
to
toggle
the
parameter
to
the
STOP
value.
LEFT
ARROW
to
shift
to
the
READY
TEMP
parameter.
STOP
to
return
to
the
STOP
MODE
MENU
and
stop
printing.
POWER ON : ****
i
Summary of Contents for 814532
Page 1: ...MANUAL Hot Quick Coder D Edition H215 AE Rev 10 English kortho...
Page 20: ...SAFETY kortho Hot Quick Coder D H215 AE Rev 10 4 4...
Page 26: ...INSTALLATION kortho Hot Quick Coder D H215 AE Rev 10 5 6...
Page 38: ...TROUBLESHOOTING kortho Hot Quick Coder D H215 AE Rev 10 7 4...
Page 40: ...MAINTENANCE kortho Hot Quick Coder D H215 AE Rev 10 8 2...
Page 42: ...DISMANTLING DISPOSAL kortho Hot Quick Coder D H215 AE Rev 10 9 2...
Page 47: ...APPENDIX B DIMENSIONS H215 AE Rev 10 kortho Hot Quick Coder D B 3 Coding unit HQC D...
Page 48: ...APPENDIX B DIMENSIONS kortho Hot Quick Coder D H215 AE Rev 10 B 4 Bracket coding unit HQC D...
Page 53: ...APPENDIX C PART LISTS ILLUSTRATIONS H215 AE Rev 10 kortho Hot Quick Coder D C 5...
Page 54: ...APPENDIX C PART LISTS ILLUSTRATIONS kortho Hot Quick Coder D H215 AE Rev 10 C 6...
Page 57: ...APPENDIX D CONNECTIONS H215 AE Rev 10 kortho Hot Quick Coder D D 3 Power I O board CPU board...
Page 62: ...APPENDIX E EC DECLARATIONS OF CONFORMITY kortho Hot Quick Coder D H215 AE Rev 10 E 2...
Page 63: ...H215 AE Rev 10 kortho Hot Quick Coder D F 1 Appendix F Quick reference...