5
1. Remove cover
2. Insert battery (9V, not included). Replace the cover.
3. Turn on the set with adjusting wheel.
4. The LED indicator (small red light) will immediately light
steadily. Make sure that no metal parts or voltage carrying
parts are nearby. Turn the wheel until the indicator light goes
off. Now the set is ready for use.
5. If the light indicator doesn‘t go on or won‘t go out (after the
set has been switched on) the set can be adjusted from the
inside. To do this, adjust the blue wheel (after switched on) by
1/2
turn and turn the potentiometer in the middle of the set
with a small screwdriver (or paperclip) slowly, until the
indicator light goes off or on. If the LED pulses continuously
(with no voltage carrying object nearby) adjust the potentio
meter farthest from the battery counterclockwise until the
LED just stops pulsing. Then test to make sure the LED will
pulse when the set is held about 2“ to 3“ away from a known
A.C. voltage source as shown in step 6. Adjust the potentio
meter additionally if necessary.
6. Hold the detector as shown in the picture and move it along
the
wall. Bigger metal parts (conduits, waterpipes) will be
indicated up to a distance of 3,5“ (9 cm). The LED will light
steadly and buzzer beeps while metal is being detected.
7. A.C. voltage carrying parts (not shielded conductors or those
within metal conduit or pipe) will be shown, with a banking
light and buzzer beeps. The indicator will light up from a
greater distance if power is running.
8. To turn the detector off (don‘t forget) turn the adjustingwheel
toward the light, until the turn-off switch is engaged.
9. Only in accordance with installation rules!
Subject to all technical alterations.
GB