Introduction

    

These operating instructions have been written for drivers, operators and the maintenance 
staff of your air conditioning unit. 

In this context, we refer implicitly to the compliance with our general installation guide-
lines.  These  can  be  obtained  from  the  KONVEKTA  technical  after  sales  service: 

[email protected]

Please observe our valid safety instructions, available under

 

www.konvekta.de/asv.html

In 

case of order placement or any other conclusion of contract the safety instructions get in-
tegral part of the contract.  

These operating instructions have

 

to

 

be

 

read

 

carefully and made use of before the first start-

up and after that regularly by each person who is involved in handling the machine: 

  Operation including troubleshooting

 

and waste disposal of fuels and auxiliary agents. 

  Servicing, inspection, repair 

  Transport 

This facilitates the handling and avoids trouble caused by improper operation. Working in 
compliance with these operating instructions increases operation reliability and service life of 
the air conditioning unit and reduces life cycle costs. 

 

Please complete these instructions by adding the national provisions for 
prevention of accidents and environmental protection. 

  These instructions are part of the air conditioning unit. Always have a copy 

at

 

hand in the driver’s cabin. 

You will certainly understand that we will not recognize any warranty claims due to un-
proper handling, inadequate maintenance, applications that do not correspond with the 
determined use, utilization of unadmitted fuels or the non-observance of safety provi-
sions. 

KONVEKTA will annul without prenotice all obligations concerning guarantee, service 
contracts etc. regardless if granted by KONVEKTA or its distributors in case other than 
original KONVEKTA spare parts or parts bought from KONVEKTA AG have been used 
for maintenance and repair. 

These operating instructions contain all necessary information to operate your air con-
ditioning

 

unit. In case you need more explanations please contact the next KONVEKTA 

service station

 

 

On our website www.konvekta.com in category >service< you will find a survey of contact details 
of all our service partners close to your location

 

 

Summary of Contents for KL30/12V

Page 1: ...6 0 49 0 66 91 76 200 Info konvekta com www konvekta com Instruction manual for KONVEKTA air conditioning units KL30 KL30T With KK2 control Version 12 or 24 volt DC Circulating air Circulating air fresh air Circulating air fresh air heating ID BBA KL30T12AC Version A03 ...

Page 2: ...3 Self test 7 4 4 Setting the required room temperature 7 4 5 Disturbance display temperature sensor error 8 4 6 Manual setting of the vaporiser fan speed 8 4 7 Outside temperature display 8 4 8 Switching between circulation air fresh air function 8 4 9 Convector heating 8 5 Maintenance Servicing 9 5 1 Compressor 9 5 2 Circulation air grid 9 5 3 Condenser battery 9 5 4 Troubleshooting 10 6 Warrant...

Page 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Page 4: ...uct is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above note...

Page 5: ...ating fresh air kg ca 46 48 With standard ventilators and or fans 1 1 Pressure switches Bar OFF Bar ON Low pressure switch LP 2 0 2 2 1 0 3 High pressure switch HP 25 1 5 18 3 0 1 2 Compressor Important In order to avoid leaks on the shaft seal of the compressor The compressor must be switched on for approx 15 minutes every four weeks This includes when the vehicle is not used for a longer period ...

Page 6: ...t a KONVEKTA Service Station Only after that you can take unit into operation On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location 3 1 Operating conditions NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be o...

Page 7: ... shows the current room temperature in the normal status 4 3 Self test If the vehicle s ignition is turned but the engine has not been started up the control unit tests itself before the switch outputs on the control unit are released If errors are not present the room temperature is displayed 4 4 Setting the required room temperature Conditioning function is switched on automatic air conditioning...

Page 8: ... activated Led 9 illuminates vaporiser fan level 2 is activated Led 10 illuminates vaporiser fan level 1 2 are activated Level 3 level 1 level 2 4 7 Outside temperature display Press simultaneously Display shows outside temperature 4 8 Switching between circulation air fresh air function Light diode illuminates fresh air function is switched on Light diode is not illuminated fresh air function is ...

Page 9: ...works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Source of supply KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 5 1 Compressor Regard the oil amounts for each type of co...

Page 10: ...nd pressure points the compressor may need to be re placed excess pressure pressure too high Check if the ring fans are running Check the safety automatic on the panel and press in Clean the condenser blades High pressure due to high outside temperature Let the unit run until the pressure is stabi lised1 Leak in the unit lack of coolant Check unit for leaks Refill coolant Drier is blocked low pres...

Page 11: ...that affect the ozone layer Law of chemicals 27 penal prescrip tions Resolution to prohibit certain ozone destroying halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and...