background image

 

 

BAKL30T12AC 

Edition: 02.03.2017

 

Page: 4/11

 

 

Information on the operating instructions

    

These operating instructions are valid for the 

a/c-units

 type

 

KL30/12V 

 

KL30T/12V 

 

KL30/24V 

 

KL30T/24V 

 

We recommend that you supplement the paperwork with the following data when starting up 
the unit. This will also be helpful for ordering replacement parts. 

 
Air-conditioning unit series no: 

 ........................................... 

 

 
 
Order no:   

 ..........................................  

 
 
Year of construction:

 

 .................. / ..............  .................   

(MM/YY) 

 

 
 
Start-up on: 

 .................. / .............. /................. 

  (DD/MM/YY) 

 

The machine is in accordance with the EC machinery directive 2006/42/EC. 

The unit contains or needs fluorinated greenhouse gas for operation and is subject 
to identification requirements in accordance with F-Gas Regulation 517/2014.

 

Due to the fact that scope of supply depends on the order, equipment of your product may 
differ in some parts of description. 
In  case  your  product  is  equipped with  details  not  shown  or  described  in  the  operating  in-
struction,  your  KONVEKTA  -Service-Station  will  always  be  at  disposal  for  informing  you 
about correct operation. 

In the course of further developments we reserve the right to technical modifications without preno-
tice.  Guarantee  and  liability  conditions  of 

KONVEKTA  AG

’s  general  business  conditions  are  not 

enlarged

 

by the above notes. 

Indications and photos should neither be copied and circulated nor used for competitor’s purposes. 
All rights according to the copyright remain expressly reserved. 

Manufacturer: KONVEKTA AG, Postfach 2280, D-34607 Schwalmstadt 

 

 

Important! 

The heating water/glycol must contain anti-freeze (adjust the mix ratio according to the supplier’s 
instructions) for machines/vehicles which are equipped with a heating/air-conditioning unit. This is 
necessary so that the heating thermal exchanger does not freeze during air-conditioning functions!  
(Standard anti-freeze filled by the vehicle manufacturer is up to –40°C.) 

Summary of Contents for KL30/12V

Page 1: ...6 0 49 0 66 91 76 200 Info konvekta com www konvekta com Instruction manual for KONVEKTA air conditioning units KL30 KL30T With KK2 control Version 12 or 24 volt DC Circulating air Circulating air fresh air Circulating air fresh air heating ID BBA KL30T12AC Version A03 ...

Page 2: ...3 Self test 7 4 4 Setting the required room temperature 7 4 5 Disturbance display temperature sensor error 8 4 6 Manual setting of the vaporiser fan speed 8 4 7 Outside temperature display 8 4 8 Switching between circulation air fresh air function 8 4 9 Convector heating 8 5 Maintenance Servicing 9 5 1 Compressor 9 5 2 Circulation air grid 9 5 3 Condenser battery 9 5 4 Troubleshooting 10 6 Warrant...

Page 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Page 4: ...uct is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above note...

Page 5: ...ating fresh air kg ca 46 48 With standard ventilators and or fans 1 1 Pressure switches Bar OFF Bar ON Low pressure switch LP 2 0 2 2 1 0 3 High pressure switch HP 25 1 5 18 3 0 1 2 Compressor Important In order to avoid leaks on the shaft seal of the compressor The compressor must be switched on for approx 15 minutes every four weeks This includes when the vehicle is not used for a longer period ...

Page 6: ...t a KONVEKTA Service Station Only after that you can take unit into operation On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location 3 1 Operating conditions NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be o...

Page 7: ... shows the current room temperature in the normal status 4 3 Self test If the vehicle s ignition is turned but the engine has not been started up the control unit tests itself before the switch outputs on the control unit are released If errors are not present the room temperature is displayed 4 4 Setting the required room temperature Conditioning function is switched on automatic air conditioning...

Page 8: ... activated Led 9 illuminates vaporiser fan level 2 is activated Led 10 illuminates vaporiser fan level 1 2 are activated Level 3 level 1 level 2 4 7 Outside temperature display Press simultaneously Display shows outside temperature 4 8 Switching between circulation air fresh air function Light diode illuminates fresh air function is switched on Light diode is not illuminated fresh air function is ...

Page 9: ...works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Source of supply KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 5 1 Compressor Regard the oil amounts for each type of co...

Page 10: ...nd pressure points the compressor may need to be re placed excess pressure pressure too high Check if the ring fans are running Check the safety automatic on the panel and press in Clean the condenser blades High pressure due to high outside temperature Let the unit run until the pressure is stabi lised1 Leak in the unit lack of coolant Check unit for leaks Refill coolant Drier is blocked low pres...

Page 11: ...that affect the ozone layer Law of chemicals 27 penal prescrip tions Resolution to prohibit certain ozone destroying halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and...

Reviews: