background image

 

 

BAKL30T12AC 

Edition: 02.03.2017

 

Page: 5/11

 

 

1.  Technical data

 

Type: 

 

KL30 

KL30T 

Coolant 

 

R134a 

GWP 

 

1.430 

Amount of coolant  

[kg] ca. 

1.4 

1.5 

Operating voltage 

or 

[Volt DC] 

12 
24 

12 
24 

Power consumption    (3 stage) at 13V: 

(3 stage) at 26V:   

[Ampere] 

44 
22 

58 
29 

Cooling power with SD7H15 

[W] 

10.000 

10.000 

Heating power  Q=80 

[Watt] 

15.000 

15.000 

Vaporiser – air volume*, free-blowing  

[m

3

/h] 3 stage 

2.000 

2.000 

Dimensions:

 

 

 

 

Length 

[mm] 

2.192 

2.192 

Width 

[mm] 

886 

886 

Height 

Installation height on vehicle roof 

[mm] 

169 

160 - 169 

169 

160 - 169 

Weight of unit, features: 

 

 

 

Circulation air 

[kg] ca. 

44 

46 

Fresh air 

[kg] ca. 

45 

47 

H fresh air 

[kg] ca. 

46 

48 

* With standard ventilators and/or fans 

1.1.  Pressure switches 

 

Bar OFF 

Bar ON 

Low pressure switch (LP) 

2 ± 0,2 

2,1 ± 0,3 

High pressure switch (HP) 

25 +1,5 

18 ± 3,0 

1.2.  Compressor 

 

Important: 

In order to avoid leaks on the shaft seal of the compressor: The compressor must be 
switched on for approx. 15 minutes every four weeks

This includes when the vehicle is not used for a longer period of time or is used without using the 
air-conditioning unit! 

 

Compressor Type 

SD7H15 

Weight (kg)  ca.

 

 

7.5 

Cooling oil 
- amount(litre) 

PAG/dependi

ng on de-

sign

3)

  

Magnet clutch 

2)

 

24V DC 

1) 

Weight without magnet clutch (with clutch ca. + 10kg). 

2) 

Ø dependent upon vehicle type

 

3) 

The schedule is included with compressor!  

(Instruction manual: TD00031A) 
 

Warning:

  

Rotation direction for 

SD7H15: 

clockwise!

 

Summary of Contents for KL30/12V

Page 1: ...6 0 49 0 66 91 76 200 Info konvekta com www konvekta com Instruction manual for KONVEKTA air conditioning units KL30 KL30T With KK2 control Version 12 or 24 volt DC Circulating air Circulating air fresh air Circulating air fresh air heating ID BBA KL30T12AC Version A03 ...

Page 2: ...3 Self test 7 4 4 Setting the required room temperature 7 4 5 Disturbance display temperature sensor error 8 4 6 Manual setting of the vaporiser fan speed 8 4 7 Outside temperature display 8 4 8 Switching between circulation air fresh air function 8 4 9 Convector heating 8 5 Maintenance Servicing 9 5 1 Compressor 9 5 2 Circulation air grid 9 5 3 Condenser battery 9 5 4 Troubleshooting 10 6 Warrant...

Page 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Page 4: ...uct is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above note...

Page 5: ...ating fresh air kg ca 46 48 With standard ventilators and or fans 1 1 Pressure switches Bar OFF Bar ON Low pressure switch LP 2 0 2 2 1 0 3 High pressure switch HP 25 1 5 18 3 0 1 2 Compressor Important In order to avoid leaks on the shaft seal of the compressor The compressor must be switched on for approx 15 minutes every four weeks This includes when the vehicle is not used for a longer period ...

Page 6: ...t a KONVEKTA Service Station Only after that you can take unit into operation On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location 3 1 Operating conditions NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be o...

Page 7: ... shows the current room temperature in the normal status 4 3 Self test If the vehicle s ignition is turned but the engine has not been started up the control unit tests itself before the switch outputs on the control unit are released If errors are not present the room temperature is displayed 4 4 Setting the required room temperature Conditioning function is switched on automatic air conditioning...

Page 8: ... activated Led 9 illuminates vaporiser fan level 2 is activated Led 10 illuminates vaporiser fan level 1 2 are activated Level 3 level 1 level 2 4 7 Outside temperature display Press simultaneously Display shows outside temperature 4 8 Switching between circulation air fresh air function Light diode illuminates fresh air function is switched on Light diode is not illuminated fresh air function is ...

Page 9: ...works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Source of supply KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 5 1 Compressor Regard the oil amounts for each type of co...

Page 10: ...nd pressure points the compressor may need to be re placed excess pressure pressure too high Check if the ring fans are running Check the safety automatic on the panel and press in Clean the condenser blades High pressure due to high outside temperature Let the unit run until the pressure is stabi lised1 Leak in the unit lack of coolant Check unit for leaks Refill coolant Drier is blocked low pres...

Page 11: ...that affect the ozone layer Law of chemicals 27 penal prescrip tions Resolution to prohibit certain ozone destroying halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and...

Reviews: