11002347AA
date of change: 20.08.2014
Page: 16/19
d.Et
Display unlock difference after finished defrost cycle
During defrost cycle it is possible that the tempera-
ture measured by the cell sensor (Pr1) rises exces-
sively (this depends on the position of the sensor
Pr1 to the evaporator).
In order to not indicate this rise, the functions con-
tained in the parameters
“
d.dL
”
(display lock during
defrost cycle)
and
“
d.Et
”
(display unlock difference
after finished defrost cycle) are used.
The parameter “d.dL” = Lb causes the indication
dEF during a defrost cycle.
Completion of defrost cycle the indication PdF is
suppressed, as the temperature Pr1 is always under
the value [”SP” + “d.Et”].
0 ÷ 30
°C/°F
30.0
30.0
30.0
30.0
30.0
d.di
Temp.
dF
d.di/dSd
off
d.tS
d.tE
ON
A
off
EP
d.di
ON
d.dE
B
(NO defrost)
d.di
off
C
time
Pr2