The Motor-Plane-/ Boat-Mode (Mode 3)
All required properties for electric powered motor airplanes and
boats are preadjusted in this mode.
·
The EMF-brake is disabled.
·
The undervoltage cut off is disabled because the decreasing
battery voltage can easily be recognized. So the maneuverability
will not be affected.
·
The overtemperature cut off and the over current cut off is
activated to cut off the motor at over load conditions.
·
The RPM limit is set to 50.000 RPM at 4-pole-motors which is
25.000 RPM at 8-pole-motors and 100.000 RPM at 2-pole-
motors.
·
The throttle characteristic is optimized for the use of propellers.
·
The throttle positions are stored during the mode programming,
so the equalizing procedure is no more in use.