![Kontron speedMOPSlcdCE User Manual Download Page 93](http://html1.mh-extra.com/html/kontron/speedmopslcdce/speedmopslcdce_user-manual_1996506093.webp)
KONTRON
speedMOPSlcdCE User’s Guide
85
Appendix E: Connector Layout
P
in
P
C
10
4
+
B
u
s
(A
)
J8
P
C
10
4
+
B
u
s
(B
)
J8
P
C
10
4
+
B
u
s
(C
)
J8
P
C
10
4
+
B
u
s
(D
)
J8
1
GND
Reserved
VCC (***)
AD00
2
VCC (***)
AD02
AD01
AD03
3
AD05
GND
AD04
AD03
4
C/BE0
AD07
GND
AD06
5
GND
AD09
AD08
GND
6
AD11
VCC (***)
AD10
GND
7
AD14
AD13
GND
AD12
8
VCC3 (**)
C/BE1
AD15
VCC3 (**)
9
SERR
GND
SB0
PAR
10
GND
PERR
VCC3 (**)
SDONE
11
STOP
VCC3 (**)
LOCK
GND
12
VCC3 (**)
TRDY
GND
DEVSEL
13
FRAME
GND
IRDY
VCC3 (**)
14
GND
AD16
VCC3 (**)
C/BE2
15
AD18
VCC3 (**)
AD17
GND
16
AD21
AD20
GND
AD19
17
VCC3(**)
AD23
AD22
VCC3 (**)
18
IS0 (AD20)
GND
IS1 (AD21)
IS2 (AD22)
19
AD24
C/BE3
VI/O
IS3 (AD23)
20
GND
AD26
AD25
GND
21
AD29
VCC (***)
AD28
AD27
22
VCC (***)
AD30
GND
AD31
23
REQ0
GND
REQ1
VI/O
24
GND
REQ2
VCC (***)
GNT0
25
GNT1
VI/O
GNT2
GND
26
VCC (***)
CLK0
GND
CLK1
27
CLK2
VCC (***)
CLK3
GND
28
GND
INTD
VCC (***)
RST
29
+12V
INTA
INTB
INTC
30
-12V
Reserved
Reserved
Reserved
Notes
: (**)
Not generated onboard of the speedMOPSlcdCE
(***)
To protect the external power lines of peripheral devices, make sure that:
- the wires have the right diameter to withstand the maximum available current
- the enclosure of the peripheral device fulfils the fire protecting requirements of
- IEC/EN 60950.
Summary of Contents for speedMOPSlcdCE
Page 1: ...speedMOPSlcdCE User s Guide Document Revision 1 2...
Page 2: ......
Page 8: ...KONTRON Contents vi speedMOPSlcdCEUser s Guide...
Page 86: ...KONTRON Appendix C Block Diagram 78 speedMOPSlcdCEUser s Guide 25 APPENDIX C BLOCK DIAGRAM...
Page 88: ...KONTRON Appendix D Mechanical Dimensions 80 speedMOPSlcdCEUser s Guide 26 1 2 Side View...
Page 90: ...KONTRON Appendix E Connector Layout 82 speedMOPSlcdCEUser s Guide 27 2 Bottom Side...