6. Product Description
KISS 4U KTC5520 – User's Guide (Version 1.01)
6.3.1.1.
Interfaces routed to the Rear Panel
On-board interfaces can be routed to the rear panel.
A detailed description of the interfaces can be found in the manual of the installed server board
(KTC5520/EATX).
You can download the relevant manual for your system from our web site at
selecting the product. See also “KISS 4U KTC5520 Systems - Configuration Guide” on our website.
6.3.2.
Power Supply
The power supply is located on the rear side of the KISS 4U KTC5520 platform.
On request, the KISS 4U KTC5520 platform can optionally be equipped with an AC wide rage PSU or a redundant AC wide
rage PSU. The integrated power supply version also depends on the ordered system version and system configuration. The
respective power supply version and the corresponding nominal voltage range can be found on the type label on the right
side of the system.
Please observe the step1 of the subsection 6.3.3 “Grounding Stud”, the section 8.1 “Power Cord
Connection” and the labels (“WARNING” and “CAUTION”) attached to the device.
6.3.3.
Grounding Stud
The grounding stud is located on the rear side of the KISS 4U KTC5520 platform (see Fig. 18, pos. 9).
The KISS 4U KTC5520 systems with grounding studs marked with a PE symbol have to be grounded by
establishing a large-area contact between the grounding stud and an appropriate grounding connection
point before connecting to the main power supply (refer to step1 of the section 8.1 “Power Cord
Connection” and the labels (“WARNING” and “CAUTION”) attached to the device.
Fig. 19: Grounding stud marked with PE symbol
Fig. 20: Unmarked grounding stud
www.kontron.com
21