CP6016
Introduction
ID 1022-3074, Rev. 2.0
Page 1 - 15
P R E L I M I N A R Y
1.6
Kontron Software Support
Kontron
is one of the few CompactPCI and VME manufacturers providing inhouse support for
most of the industry-proven real-time operating systems that are currently available. Due to its
close relationship with the software manufacturers,
Kontron
is able to produce and support
BSPs and drivers for the latest operating system revisions thereby taking advantage of the
changes in technology.
General
Mechanical
6U, 4HP, CompactPCI-compliant form factor
Power Consumption
See Chapter 5 for details.
Temperature Ranges
Operational:
0°C to +60°C
Standard
Storage: -55°C to +85°C
Without hard disk and without battery
Battery
3.0V lithium battery for RTC with battery socket.
Recommended type: CR2025
Temperature ranges:
Operational: -20°C to +70°C
typical (refer to the battery manufacturer’s
specifications for exact range)
Storage: -55°C to +70°C
typical (no discharge)
Climatic Humidity
93% RH at 40 °C, non-condensing (acc. to IEC 60068-2-78)
Dimensions
233.35 mm x 160 mm
Board Weight
837 g (with two CompactPCI connectors, heat sink and SO-RDIMM modules
but without mezzanine cards)
880 g (with five CompactPCI connectors, heat sink and SO-RDIMM modules
but without mezzanine cards)
Table 1-1:
CP6016 Main Specifications (Continued)
FEATURES
SPECIFICATIONS
Note ...
When a battery is installed, refer to the operational specifica-
tions of the battery as this determines the storage tempera-
ture of the CP6016 (See "Battery" below).
Note ...
When additional components are installed, refer to their opera-
tional specifications as this will influence the operational and stor-
age temperature of the CP6016.