![Kontron CP3002 User Manual Download Page 57](http://html1.mh-extra.com/html/kontron/cp3002/cp3002_user-manual_1996259057.webp)
CP3002
Functional Description
ID 1042-9252, Rev. 2.0
Page 2 - 19
P R E L I M I N A R Y
2.11.10.2 CompactPCI Connectors J1 and J2 Pinouts
The CP3002 is provided with two 2 mm x 2 mm pitch female CompactPCI connectors, J1 and
J2.
The legacy IDE interrupts INTP (CompactPCI specification pin D4) and INTS (CompactPCI
specification pin E4) are not implemented on the CP3002. Therefore, pins D4 and E4 are re-
served.
The IPMB system management bus (CompactPCI specification pins A4, B17, C17) is not im-
plemented on the CP3002. Therefore, pin A4 is not connected and pins B17 and C17 are re-
served.
For further information regarding the above-mentioned reserved pins, please contact Kontron.
Table 2-12: CompactPCI Connector J1 System Controller Slot Pinout
PIN
ROW Z
ROW A
ROW B
ROW C
ROW D
ROW E
ROW F
25
NC
5V
REQ64#
ENUM#
3.3V
5V
GND
24
NC
AD[1]
5V
V(I/O)
AD[0]
ACK64#
GND
23
NC
3.3V
AD[4]
AD[3]
5V
AD[2]
GND
22
NC
AD[7]
GND
3.3V
AD[6]
AD[5]
GND
21
NC
3.3V
AD[9]
AD[8]
M66EN
C/BE[0]#
GND
20
NC
AD[12]
GND
V(I/O)
AD[11]
AD[10]
GND
19
NC
3.3V
AD[15]
AD[14]
GND
AD[13]
GND
18
NC
SERR#
GND
3.3V
PAR
C/BE[1]#
GND
17
NC
3.3V
RSV
RSV
GND
PERR#
GND
16
NC
DEVSEL#
PCIXCAP
V(I/O)
STOP#
LOCK#
GND
15
NC
3.3V
FRAME#
IRDY#
BDSEL#
TRDY#
GND
12-14
Key Area
11
NC
AD[18]
AD[17]
AD[16]
GND
C/BE[2]#
GND
10
NC
AD[21]
GND
3.3V
AD[20]
AD[19]
GND
9
NC
C/BE[3]#
NC
AD[23]
GND
AD[22]
GND
8
NC
AD[26]
GND
V(I/O)
AD[25]
AD[24]
GND
7
NC
AD[30]
AD[29]
AD[28]
GND
AD[27]
GND
6
NC
REQ0#
CPCI_PRESENT# 3.3V
CLK0
AD[31]
GND
5
NC
NC
NC
RST#
GND
GNT0#
GND
4
NC
NC
HEALTHY#
V(I/O)
RSV
RSV
GND
3
NC
INTA#
INTB#
INTC#
5V
INTD#
GND
2
NC
TCK
5V
TMS
NC
TDI
GND
1
NC
5V
NC
TRST#
NC
5V
GND