CP3002
Introduction
ID 1042-9252, Rev. 2.0
Page 1 - 17
P R E L I M I N A R Y
Furthermore, boards providing ruggedized service and conformal coating comply with the fol-
lowing standards as well.
Table 1-4:
Add. Standards for CP3002 with Rug. Service and Conformal Coating
TYPE
ASPECT
STANDARD
REMARKS
Environmental
Random Vibration
(Broadband)
VITA 47, Class V1
Test parameters:
5-100 (Hz) frequency range
0.04 (g²/Hz) acceleration
60 min//axis test duration
3 axes
Single Shock
VITA 47, Class OS1
Test parameters:
20 (g) acceleration
11 (ms) half-sine shock duration
3 number of shocks per direction (total: 18)
6 directions
5 (s) recovery time
Temperature
VITA 47, Class AC3
Test parameters:
-20°C to +70°C operating temperature
forced airflow 3 m/s
Above +65°C, the CPU performance may be
reduced, depending on application demands and
system cooling capabilities.
VITA 47, Class C4
Test parameters:
-55°C to +105°C storage temperature
Climatic Humidity
VITA 47
Test parameters:
30°C to 60°C, 10*24h cyclic temperature
95% RH
Note ...
When additional modules are used with a ruggedized and coated CP3002,
please refer to the specifications of the respective module as this may have an
impact on the environmental conditions of the board.