COMe-bEP7 Module User Guide
www.kontron.com
// 90
Sub-Screen
Second Level Sub-screen/Description
c.
Auto – Hardware monitor controls cooling, similar to ACPI
based ‘Active Cooling’, without producing a software load to
the system.
[Disable, Manual, Auto]
External Fan–
Fan Pulse>
Displays number of pulse fan produces during 1 revolution
(Range: 1-4)
[2]
External Fan-
Fan Trip point>
Displays temperature at which fan accelerates. (Range:
20°C to 80°C)
[50]
External Fan-
Trip Point Speed>
Displays Fan speed at trip point in %. Minimum value is
30%
Fan always runs at 100% at TJmax (-10°C)
[50]
External Fan Reference
Temperature>
Determines temperature source used for automatic fan
control
[Module Temperature, CPU Temperature ]
Additional information External Fan
An external fan can be connected to baseboard.
The external fan control lines are routed via the COMe connector.
5.0 V Standby>
Read only field
Displays standby voltage
Batt Volt. at COMe Pin>
Read only field
Displays battery voltage at COMe pin
Widerange Vcc>
Read only field
Displays wide range VCC
12.4.11.
Serial Port Console Redirection Sub-Menu
Table 40: Serial Port Console Redirection Sub-Screens
Sub-Screen
Second Level Sub
Further Sub-Screens/Description
COM0 Console
Redirection>
or
COM1 Console
Redirection>
Enables or disables console redirection via COMe module’s COM0 or
COM1.
[Enabled , Disabled]
COM0 Console
Redirection
Settings>
The settings specify how the host computer and the remote
computer (which the user is using) will exchange data. Both
computers should have the same or compatible settings.