COMe-bEP7 Module User Guide
www.kontron.com
// 89
Sub-Screen
Second Level Sub-
screen/Description
Further Sub-Screens/Description
I2C IRQ #>
[Disabled, IRQ 5, IRQ 6, IRQ 7, IRQ 10, IRQ 11, IRQ 12, IRQ 14, IRQ 15]
PWRBTN IRQ
#>
[Disabled, IRQ 5, IRQ 6, IRQ 7, IRQ 10, IRQ 11, IRQ 12, IRQ 14, IRQ 15]
12.4.10.
H/W Monitor Sub-Menu
Table 39: H/W Monitor Sub-Screens
Sub-Screen
Second Level Sub-screen/Description
Read only field
Hardware Monitor name
CPU Temperature>
Read only field.
Displays CPU die temperature in °C.
Module Temperature>
Read only field.
Displays module temperature in °C.
CPU Fan –
Fan Control>
Set fan control mode.
‘Disable’ will totally stop the fan.
a.
Disable - stops fan.
b.
Manual – manually sets the fan.
c.
Auto – Hardware monitor controls cooling, similar to ACPI
based ‘Active Cooling’, without producing a software load to
the system.
[Disabled, Manual, Auto]
CPU Fan –
Fan Pulse>
Displays number of pulses fan produces during 1
revolution. (Range: 1-4)
[2]
CPU Fan –
Fan Trip Point>
Displays temperature at which the fan accelerates.
(Range: 20°C – 80°)
[50]
CPU Fan –
Trip Point Speed>
Displays Fan speed at trip point in %. Minimum value is 30
%.
Fan always runs at 100 % at TJmax (-10°C).
[50]
CPU Fan – Reference
Temperature>
Determines temperature source used for automatic fan
control
[Module Temperature, CPU Temperature ]
External Fan-
Fan Control>
Set fan control mode.
‘Disable’ will totally stop the fan.
a.
Disable - stops fan.
b.
Manual – manually sets the fan.