THE FUEL FILTER IN THE FUEL SUPPLY PIPELINE
THE FUEL FILTER IN THE FUEL SUPPLY PIPELINE
This filter has to be replaced every 200 operating hours. It’s located under the fuel tank on the fuel hose
through which fuel enters the engine from the tank. To replace it:
Please note that if you fail to start up power plants, the
batteries may run outtherefore, the battery must be fully
charged before starting operation.
IMPORTANT!
Diagnostics and troubleshooting should be performed by
a specialist in diesel generators.
WARNING!
Fuel filtr
1. Loosen the metal hose clamps, located next to the fuel
valve to drain the fuel.
2. Drain the fuel to some special volume.
3. Loosen metal staples on both sides of the fuel filter.
4. Remove the filter.
5. Install new filter, paying attention to the arrow shown.
The filter should be installed in the fuel passage direction.
6. Tighten the bracket on the fuel hose.
ACCUMULATOR MAINTENANCE
13
In
Könner & Söhnen
®
models with electric start you should periodically perform battery voltage checks.
The generator battery has a voltage of 12V and if the voltage is lower, you should perform battery charging
with the help of an external charger.
To avoid discharging the battery, it is recommended to run the generator at least once a month for 30
minutes. If the generator is not used for a long time, please disconnect the battery from the terminals. The
battery that comes with the generator does not require additional maintenance and filling of electrolyte.
The storage area of the power plant should be dry, well-ventilated and out of the reach of children.
LONG-TERM STORAGE OF THE POWER PLANT:
LONG-TERM STORAGE OF THE POWER PLANT:
Long-term storage can affect the engine and the power plant as a whole. This impact can be reduced by
proper preparation and storage of the power plant.
Engine storage.
The engine must undergo a conservation procedure, which includes cleaning the engine
and replacing all liquids with fresh or preservatives. Please contact your local dealer for more information
about engine storage.
Storage of AC generator equipment.
When the alternator is stored, condensation can form in the
windings. To reduce condensation, store the generator set in a dry place. Please contact your local dealer
for more information about storing alternators.
Battery storage.
When the battery is in storage, it should be charged every 12 weeks (8 weeks in tropical
climates) to a fully charged state.
STORAGE
14
POSSIBLE FAILURES AND SOLUTIONS
15