3. 

In the above SMS operation, you will receive a reply message for confirmation after sending message command to 

the host. Such as:   

DisArm, Sms:ON, Phone:ON, Siren:ON, Center Tel:OFF, Arm Center Tel:OFF, DisArm Center Tel:OFF 

If the replied message is about the current status of the host, you may have sent wrong command. 

4.    You can also send inquiry command to check out the present status of the host. 

5.    When the external power is cut off, the system will send SMS “Power changer off” to inform. When the external 

power resumed, the system will send SMS “Power changer on” to inform. 

 
How to use remote controllers 
 

 

 
 

There are four buttons on the remote controller:

 

Out Arm key. Press this button, the signal LED flash slowly in orange for 10 seconds, system is in arm wait status. 10 

seconds later, the signal LED flash slowly in green, system is in out arm status now. You can set out arm mode when no 

one is at home, all the detectors at home will be in working mode.   

Home Arm key. Press this button, the signal LED flash slowly in orange for 10 seconds, system is in arm wait status. 

10 seconds later, the signal LED will flash quickly in green, system is in home arm status now. You can set home arm 

mode when there is some one at home, sensors in inner defense zone will be invalid, but sensors in other defense zones 

still work normally. 

Disarm key. Press this button, all the detectors are disarmed, the light on panel will keep on in green.   

Alarm key. Press this button, the light on panel will flash in red; the system will be alarming, and the host will send the 

SMS and dial out. 

 
How to add more detectors

 

You can add more sensors and detectors, such as wireless door sensors, PIR sensors, gas and smoke detectors into the 

host. 

1) Add sensors ready to work when you set both Out Arm and Home Arm: 

When  the GSM  host  begins  to  be  powered on,  the  status  LED  light  on  panel  will  be  red  for  20  seconds,  this  is  code 

learning mode. You can trigger the sensors or detectors, and the red LED will flash to show it is coded successfully into 

the host. 

Summary of Contents for KL-H21B

Page 1: ...com U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen GSM Home Alarm...

Page 2: ...upply with back up 1pc Installation user manual 1pc Installation guide 1 Insert SIM in alarm unit Press the yellow point on top of the main unit with a pencil tip or other tools SIM tray will come out...

Page 3: ...cted with any number of wired sensors as long as total resistance is under 220 ohms When these sensors are triggered the alarming message will be Wired Activated 1 3 6 Connecting switched output devic...

Page 4: ...GND power ground How to setup the alarm phone numbers and SMS 1 You can send command to the host to setup 5 groups of alarm phone numbers The format is Password operation code content 123456 51 139075...

Page 5: ...o arm status or you may send command 123456 1 1 to the host to change the host into arm status the signal LED will flash in green in arm status 1 Under arm status any port of input I1 I2 I3 touches gr...

Page 6: ...arm of single defense zone 39 Turn off alarm of zone wireless zone 1 16 wire zone 21 23 NOTE disarm of single defense zone 50 show preset phone number in the host 51 First group phone number 0 15bit 5...

Page 7: ...al LED flash slowly in green system is in out arm status now You can set out arm mode when no one is at home all the detectors at home will be in working mode Home Arm key Press this button the signal...

Page 8: ...m Keep pressing the reset button then power on the system Siren beeps once or LED flashes once it shows reset is successful All registered detectors have been deleted You can register them again with...

Page 9: ...konlen com MSN konlensales hotmail com Skype securitykonlen 8 The following sensors can be optional Additional wireless products Optional sensors detectors are packed separately It includes remote co...

Page 10: ...less Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current 20 mA Transmission Current 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m...

Reviews: