Konlen KL-H21B Installation And User Manual Download Page 2

 

KONLEN TECHNOLOGY LIMITED

 

Website: www.konlen.com

 

U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China 

Tel: +86-(0)755-86082432 E-mail: 

[email protected]

 MSN: 

[email protected]

 Skype: securitykonlen 

Brief Introduction: 

 

GSM 900/1800/1900 bands, can be used in most parts of the world 

 

Full duplex communication with the host 

 

Monitor the scene environment 

 

Voice and message alert             

 

Set alarm ON or OFF by remote controller 

 

Can set Home Arm and Out Arm mode 

 

Call in to set alarm ON, OFF, Monitor, Output, Intercom. 

 

Send SMS to set alarm ON, OFF, Monitor, Output 

 

5 group phone + room  1 group alarm monitor center phone number 

 

2 group phone to report arm and disarm status 

 

Can program 7 groups of alarm messages 

 

3 zones for wired detector 

 

16 zones for wireless detector   

 

2 outputs, can be used with external circuit to control home appliance 

 

Easily set ON or OFF for every wired or wireless detector 

 

SMS inform if external power failure or recovery 

 

Basic Kit contains:

 

-

 

Alarm system ( alarm host ) – 1 pc. 

-

 

Wireless PIR detector – 1 pc. 

-

 

Wireless door (gap) sensor – 1 pc. 

-

 

Remote controller – 2 pcs. 

-

 

Antenna – 1pc. 

-

 

Mini wired siren 110dB/0.3m – 1 pc. 

-

 

Power supply with back-up – 1pc. 

-

 

Installation/user manual – 1pc. 

 

Installation guide: 

1. Insert SIM in alarm unit. 

Press the yellow point on top of the main unit with a pencil tip or other tools, SIM tray will come out. Put the SIM 

card carefully into the tray, and make sure the metal contacts of the SIM to be down. 

Note: Before inserting SIM card into alarm unit, using a regular mobile phone to do the following steps: 

-

 

Set PIN code request to off. 

-

 

Delete all stored numbers. 

2. Connect the antenna.

 

Screw the antenna to the connection on top of the main unit. Take care not to over-tight the nut or let it loose! 

3. Insert the power supply. 

Connect the host with the adaptor. The host need 9V-12V DC, must be over 1000mA current. 

 

The signal status LED on the main unit panel will turn to red and last for 20 seconds, this is code learning 

mode, system is waiting for wireless detectors to be coded into the host; 

 

After 20 seconds, the signal status LED will turn to orange, and begin to flash, indicating system is checking 

SIM card and search for GSM network; 

 

After main unit finish checking the host, if the signal status LED turns to green and flashes slowly, it shows 

alarm phone number have been saved in the host, and the host is in arm status. If the signal status LED keeps 

on in green, it shows phone numbers have not been saved in the host, and the host is in disarm status. You can   

Summary of Contents for KL-H21B

Page 1: ...com U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen GSM Home Alarm...

Page 2: ...upply with back up 1pc Installation user manual 1pc Installation guide 1 Insert SIM in alarm unit Press the yellow point on top of the main unit with a pencil tip or other tools SIM tray will come out...

Page 3: ...cted with any number of wired sensors as long as total resistance is under 220 ohms When these sensors are triggered the alarming message will be Wired Activated 1 3 6 Connecting switched output devic...

Page 4: ...GND power ground How to setup the alarm phone numbers and SMS 1 You can send command to the host to setup 5 groups of alarm phone numbers The format is Password operation code content 123456 51 139075...

Page 5: ...o arm status or you may send command 123456 1 1 to the host to change the host into arm status the signal LED will flash in green in arm status 1 Under arm status any port of input I1 I2 I3 touches gr...

Page 6: ...arm of single defense zone 39 Turn off alarm of zone wireless zone 1 16 wire zone 21 23 NOTE disarm of single defense zone 50 show preset phone number in the host 51 First group phone number 0 15bit 5...

Page 7: ...al LED flash slowly in green system is in out arm status now You can set out arm mode when no one is at home all the detectors at home will be in working mode Home Arm key Press this button the signal...

Page 8: ...m Keep pressing the reset button then power on the system Siren beeps once or LED flashes once it shows reset is successful All registered detectors have been deleted You can register them again with...

Page 9: ...konlen com MSN konlensales hotmail com Skype securitykonlen 8 The following sensors can be optional Additional wireless products Optional sensors detectors are packed separately It includes remote co...

Page 10: ...less Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current 20 mA Transmission Current 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m...