How to control the host 

1.

 

Sending message to the host phone number (SIM Card number) 

Send the message to the host: enter password 123456#, add the following command to set the host; 

2.

 

Calling the host phone number (SIM Card number)   

Call in the host and enter password 123456#, then input the following command to set the host: 

 

Com 

Function 

Com 

Function 

1#1# 

Outdoor arm* (all detectors work) 

1#2# 

Indoor arm (part detectors work) 

1#0# 

Disarm *(all detectors not work) 

 

 

3#1# 

Sounding immediately 

3#0# 

Stop sounding 

4#1# 

Open listen-in (use phone key )* 

4#0# 

Closed listen-in (use phone key ) 

11#1# 

Need siren sound when alarming * 

11#0# 

No siren sound when alarming 

12#1# 

Sending SMS when alarming * 

12#0# 

No SMS when alarming 

15#1# 

Dial phone number when alarming *   

15#0# 

Just alarm and no dialing 

16#1# 

Disable Relay close 3 Min when alarming 

16#0#* 

Set Relay close 3 Min when alarm* 

30## 

show the arm and disarm status of every zone   

31#--# 

Change password. Enter a new password (1-6 bit). 

38#--# 

Set up alarm of zone (wireless zone: 1-16; wire zone: 21-23) 

NOTE: arm of single defense zone

 

39#--# 

Turn off alarm of zone (wireless zone: 1-16; wire zone: 21-23) 

NOTE: disarm of single defense zone

 

50## 

show preset phone number in the host 

51#--# 

First group phone number(0-15bit) 

52#--# 

Second group phone number(0-15bit) 

53#--# 

Third group phone number(0-15bit) 

54#--# 

fourth group phone number(0-15bit) 

55#--# 

Fifth group phone number(0-15bit) 

 

80## 

show preset SMS in the host 

81#--# 

First group Message(0-24bit) 

82#--# 

Second group Message(0-24bit) 

83#--# 

Third group Message(0-24bit) 

84#--# 

Fourth group Message(0-24bit) 

85#--# 

Fifth group Message(0-24bit) 

86#--# 

Sixth group Message(0-24bit) 

87#--# 

Seventh group Message(0-24bit) 

 

90## 

Show Output status in the host 

91#1# 

Set Output 1 change to high 

91#0# 

Set Output 1 change to low 

92#1# 

Set Output 2 change to high 

92#0# 

Set Output 2 change to low 

93#1# 

Set talk to the host available (Output 3) 

93#0# 

Set talk to the host unavailable (Output 3) 

94#1# 

Set Relay to be connected 

94#0# 

Set Relay to be disconnected 

95#1# 

Set alarm when line input 1 open   

95#0# 

Set alarm when line input 1 connect to Gnd* 

96#1# 

Set alarm when line input 2 open 

96#0# 

Set alarm when line input 2connect to Gnd*   

97#1# 

Set alarm when line input 3 open 

97#0# 

Set alarm when line input 3connect to Gnd*   

Note:   

1.    Above table, ‘ * ’ stands for default setting. 

2.    In the above phone operation, one beep shows the number your input is successful, a long beep shows the sentence 

you input is successful, two short beeps show sentence you input is failed, you should try again. 

Summary of Contents for KL-H21B

Page 1: ...com U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen GSM Home Alarm...

Page 2: ...upply with back up 1pc Installation user manual 1pc Installation guide 1 Insert SIM in alarm unit Press the yellow point on top of the main unit with a pencil tip or other tools SIM tray will come out...

Page 3: ...cted with any number of wired sensors as long as total resistance is under 220 ohms When these sensors are triggered the alarming message will be Wired Activated 1 3 6 Connecting switched output devic...

Page 4: ...GND power ground How to setup the alarm phone numbers and SMS 1 You can send command to the host to setup 5 groups of alarm phone numbers The format is Password operation code content 123456 51 139075...

Page 5: ...o arm status or you may send command 123456 1 1 to the host to change the host into arm status the signal LED will flash in green in arm status 1 Under arm status any port of input I1 I2 I3 touches gr...

Page 6: ...arm of single defense zone 39 Turn off alarm of zone wireless zone 1 16 wire zone 21 23 NOTE disarm of single defense zone 50 show preset phone number in the host 51 First group phone number 0 15bit 5...

Page 7: ...al LED flash slowly in green system is in out arm status now You can set out arm mode when no one is at home all the detectors at home will be in working mode Home Arm key Press this button the signal...

Page 8: ...m Keep pressing the reset button then power on the system Siren beeps once or LED flashes once it shows reset is successful All registered detectors have been deleted You can register them again with...

Page 9: ...konlen com MSN konlensales hotmail com Skype securitykonlen 8 The following sensors can be optional Additional wireless products Optional sensors detectors are packed separately It includes remote co...

Page 10: ...less Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current 20 mA Transmission Current 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m...

Reviews: