416739/A
91
3
Connect the video cable from the Processor Unit to the display. (C5)
The display cable is often physically attached to the display, and terminated in the
“computer end” with a male connector. If the cable is not attached, it is normally
provided with the display.
The graphic adapter on the rear side of the Processor Unit provides two DVI connectors,
one for HDMI and two for Mini DisplayPort. Choose the connector that fits your
display cable. If you have two displays both can be connected simultaneously, and can
use the operating system functionality to set up different presentations.
Keep the display cable as short as possible. If the cable is too long, it may pick up
electric noise, and this will reduce the image quality.
To learn more about the various video standards, explore these Wikipedia pages.
•
•
•
4
(Optional) Connect the cable from the Processor Unit to the keyboard. (C6)
5
Connect the cable from the Processor Unit to the mouse (or another similar device).
(C7)
6
Connect the Ethernet cable from the Processor Unit to the Wideband Transceiver
(WBT). (C8)
Note
It is very important that a high-quality Ethernet cable is used. You must use CAT-5E
STP (Shielded Twisted Pair) quality or better. If you use a cable with lower bandwidth
capacity you will reduce the ES80 performance. Do not connect the Processor Unit to
the Wideband Transceiver (WBT) using an existing local area network (LAN).
Depending on the operational requirements, one or more Wideband Transceiver (WBT)
units may be used in the complete ES80 system. An Ethernet switch is required if more
than one Wideband Transceiver (WBT) is used.
For more information, see the cable details:
•
RJ45 High speed Ethernet cable (1000Base-t), page 125
7
(Optional) Connect the Ethernet cable from the Processor Unit to the local area network
(LAN). (C9)
For more information, see the cable details:
•
Summary of Contents for Simrad ES80
Page 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Page 2: ......
Page 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Page 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Page 309: ......
Page 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Page 311: ......
Page 312: ...Installation Manual Simrad ES80 ...