90
416739/A
Note
All electronic installations and corresponding wiring must be in accordance with the vessel's
national registry and corresponding maritime authority and/or classification society.
Only skilled and authorized personnel can install the ES80 cables.
Kongsberg Maritime will not accept any responsibility for errors, malfunctions or damage
to system or personnel caused by improper wiring.
Related topics
Installing the ES80 cables, page 89
Cable layout and interconnections, page 79
Cable drawings and specifications, page 116
Basic cable requirements, page 143
Installing the ES80 topside cables
The topside/bridge cables include those used to connect the ES80 Processor Unit and the
display to each other, to AC mains power, and to external devices. One high capacity
Ethernet cable connects the Processor Unit to the Wideband Transceiver (WBT).
Procedure
1
Connect the power cables.
a
Connect the power cable from the display to the AC power outlet. (C1)
b
Connect the power cable from the Processor Unit to the AC power outlet. (C2)
Standard commercial AC mains cables are used. Each cable is supplied with the
relevant unit. The typical cable length is between 1,5 and 2 meters. If this is too short
you must use an extension cable (not recommended), mount a new power outlet within
range, or make your own power cable with sufficient length.
For more information, see the cable details:
•
AC power cable using IEC C13 inline socket, page 117
2
Connect the ground cables.
a
If applicable, connect the ground cable from the display to vessel ground. (C3)
b
Connect the ground cable from the Processor Unit to vessel ground. (C4)
These cables must be provided by the installation shipyard. For more information,
see the cable details:
•
Simrad ES80 Installation Manual
Summary of Contents for Simrad ES80
Page 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Page 2: ......
Page 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Page 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Page 309: ......
Page 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Page 311: ......
Page 312: ...Installation Manual Simrad ES80 ...