• Place the transducer cables in a metal conduit all the way from the transducer to the
transceiver. Terminate the conduit as close to the transducer and transceiver as possible.
• Make sure that the transducer cables are completely separated from other cables, boxes,
other potential noise sources.
• Make sure that all units are properly grounded.
• Use shielded cables with correct grounding.
• Separate the ES80 cables from other cables with high voltages, large currents or
transients. Place all high voltage power cables in metal conduits.
• If you more than one Wideband Transceiver (WBT), install these in such a way that the
transducer cables have the maximum distance to the power and Ethernet cables.
• Ensure maximum physical distance between the Wideband Transceiver (WBT) and
the Power Supply Unit.
• Ensure maximum physical distance between each Power Supply Unit.
• If possible, install the transceivers in a sonar room that is electrically shielded.